Install a dummy cabled-riser cage

Use this information to install a dummy cabled-riser cage.

Note

A dummy cabled-riser cage is an empty riser cage installed in the tray. It contains no adapters, and a riser cage filler is installed in it. For SC777 V4, the dummy cabled riser cage is installed in slot 3 and slot 4, while slot 2 and slot 5 are installed with riser cages with adapters.

Figure 1. Dummy cabled-riser cage in slot 3 and slot 4 in SC777 V4 tray

About this task

Attention

Procedure

  1. A filler was removed from the defect dummy cabled-riser cage. Install the filler to the new dummy cabled-riser cage.
    Figure 2. Installing filler to the dummy cabled-riser cag

  2. Install the dummy cabled-riser cage to slot 3 or slot 4 in the tray.
    1. Install the dummy cabled-riser cage to the water loop.
    2. Fasten the PH 1 captive screw to secure the dummy cabled-riser cage to the water loop.
    Figure 3. Installing the cabled-riser cage

    Note
    The cabled-riser cage must be installed in slot 3 or slot 4.
    Figure 4. Dummy cabled-riser cage designated slots

After you finish
  1. Complete cable routing. See Internal cable routing.

  2. Install the cross bar. See Install the cross bar.

  3. Install the tray cover. See Install the tray cover.

  4. Install the tray into the enclosure. See Install a tray in the enclosure.

  5. Connect all required external cables to the solution.
    Note
    Use extra force to connect QSFP cables to the solution.
  6. Check the power LED on each node to make sure it changes from fast blink to slow blink to indicate all nodes are ready to be powered on.