2.5-inch drive backplane cable routing (server model with four PCIe risers)
Follow the instructions in this section to learn how to do 2.5-inch drive backplane cable routing for the server model with four PCIe risers.
- Remove the fans. See Remove a fan.
- Remove the fan cage. See Remove the fan cage.
Connections between connectors; 1↔1, 2↔2, 3↔3, ... n↔n
The Cable PN or FRU PN can be found on the label attached to the cable.
When routing the cables, make sure that all cables are routed appropriately through the corresponding cable guides and cable clips.
The AnyBay backplane is used as a pure NVMe backplane when no RAID/HBA adapters are installed.
Power cable routing
![]() |
| From (Backplane) | To (System board assembly) | Cable |
|---|---|---|
1 BP1: PWR | 1 BP3 PWR | 6P+6S to 6P+6S (150 mm) |
2 BP2: PWR | 2 BP5 PWR | 6P+6S to 6P+6S (150 mm) |
3 BP3: PWR | 3 BP8 PWR | 6P+6S to 6P+6S (150 mm) |
NVMe cable routing
| BP 1 NVMe cable routing | BP 2 NVMe cable routing | BP 3 NVMe cable routing |
|---|---|---|
![]() | ![]() | ![]() |
| From (Backplane) | To (System board assembly) | Cable |
|---|---|---|
| 1a BP1: NVMe 0-1 | 1a NVMe 10 | MCIO x8 to MCIO x8 (420 mm) |
| 1b BP1: NVMe 2-3 | 1b NVMe 9 | MCIO x8 to MCIO x8 (420 mm) |
| 1c BP1: NVMe 4-5 | 1c NVMe 1 | Swift x8 to MCIO x8 (150 mm) |
| 1d BP1: NVMe 6-7 | 1d NVMe 2 | Swift x8 to MCIO x8 (150 mm) |
| 2a BP2: NVMe 0-1 | 2a NVMe 3 | Swift x8 to MCIO x8 (150 mm) |
| 2b BP2: NVMe 2-3 | 2b NVMe 4 | Swift x8 to MCIO x8 (150 mm) |
| 2c BP2: NVMe 4-5 | 2c NVMe 5 | Swift x8 to MCIO x8 (150 mm) |
| 2d BP2: NVMe 6-7 | 2d NVMe 6 | Swift x8 to MCIO x8 (150 mm) |
| 3a BP3: NVMe 0-1 | 3a NVMe 7 | Swift x8 to MCIO x8 (150 mm) |
| 3b BP3: NVMe 2-3 | 3b NVMe 8 | Swift x8 to MCIO x8 (150 mm) |
| 3c BP3: NVMe 4-5 | 3c NVMe 12 | MCIO x8 to MCIO x8 (420 mm) |
| 3d BP3: NVMe 6-7 | 3d NVMe 11 | MCIO x8 to MCIO x8 (420 mm) |
SAS/SATA cable routing
Based on the location of the adapter, select the corresponding routing path for SAS/SATA cable from the following table.
| SAS/SATA cable routing to riser A | SAS/SATA cable routing to riser B | |
|---|---|---|
![]() | ![]() | |
| SAS/SATA cable routing to riser D | SAS/SATA cable routing to riser C | |
![]() | ![]() | |
| From | To | Cable |
| 1 Backplane 1: SAS/SATA | 1 RAID/HBA adapter |
|
| 2 Backplane 2: SAS/SATA | 2 RAID/HBA adapter |
|
| 3 Backplane 3: SAS/SATA | 3 RAID/HBA adapter |
|