Media tray (on front):- One DVD drive (can be either a CD-RW/DVD-ROM or DVD/RW drive)
- Two USB v2.0 ports
- Front system LED panel
- Two battery backup unit bay locations, which support the SAS RAID controller modules
Blade bays (on front): Six hot-swap blade server bays Disk storage module bays (on front): Two storage bays, each containing up to six 3.5-inch disk drive bays or twelve 2.5-inch disk drive bays. Module bays (on rear):- One hot-swap advanced management module bay
- Four hot-swap power module bays
- Four hot-swap fan module bays
- Four hot-swap I/O module bays
- One hot-swap serial pass-thru module bay
Power modules:- Minimum: Two hot-swap power modules.
- Maximum: Four hot-swap power modules
Cooling: Four variable-speed, hot-swap fan modules Two fans in each power supply cool the disk storage modules Management module:- One hot-swap advanced management module
| Environment:- Air temperature:
- BladeCenter S system on:
- Altitude: 0 to 914 m (3000 ft) 10° to 35°C (50° to 95°F)
- Altitude: 914 m to 2134 m (3000 ft to 7000 ft) 10° to 32°C (50° to 90°F)
- BladeCenter S system off: -40° to 60°C (-40° to 140°F).
- Humidity: 8% to 80%
- Acoustics: declared sound power level: 6.3 to 6.8 bels
Electrical input:- Sine-wave input (50 - 60 Hz single-phase) required
- Input voltage (110 V ac):
- Minimum: 100 Vrms
- Maximum: 127 Vrms
- Input voltage (220 V ac):
- Minimum: 200 Vrms
- Maximum: 240 Vrms
Heat output: Approximate heat output in British thermal units (BTU) per hour: - Minimum configuration: 1365 Btu per hour (400 watts)
- Maximum configuration: 11942 Btu per hour (3500 watts)
|