network test-link show
Display test results
Availability: This command is available to cluster administrators at the advanced privilege level.
Description
The network test-link show command displays the results of prior network test-link run-test commands.
The test results are stored non-persistently and can be viewed using the network test-link show command. Results include input parameters, the bandwidth achieved, and the date and time of the test.
Parameters
- { [-fields <fieldname>, ...]
- If you specify the -fields <fieldname>, ... parameter, the command output also includes the specified field or fields. You can use '-fields ?' to display the fields to specify.
- | [-instance ]}
- If you specify the -instance parameter, the command displays detailed information about all fields.
- -node {<nodename>|local} - Node
- Selects the nodes that match this parameter value. Use this parameter to display the test results specific to a node. By default, the test results across all nodes are shown.
- -vserver <vserver> - Vserver
- Use this parameter to display the test results specific to a Vserver. Use DC (Data Channel) Vserver option only in an ONTAP Select or ONTAP Cloud cluster to show network performance of links hosting DC LIFs. DC Vserver is a special Vserver that hosts LIFs that are used to mirror data aggregates to partner node
- [-destination <Remote InetAddress>] - Destination
- Use this parameter to display the test results associated with the specified destination.
- [-timestamp <MM/DD/YYYY HH:MM:SS>] - Time of Test
- Use this parameter to display the test results with the specified timestamp.
- [-bandwidth <double>] - MB/s
- Use this parameter to display the test results only matching the specified bandwidth.
Examples
The following example runs a test between the cluster LIFs twice and then demonstrates the show command results:
cluster1::*> network test-link run-test -node node2 -vserver Cluster -destination 172.31.112.173
Node: node2
Vserver: Cluster
Destination: 172.31.112.173
Time of Test: 4/25/2016 10:37:52
MB/s: 29.9946
cluster1::*> network test-link run-test -node node2 -vserver Cluster -destination 172.31.112.173
Node: node2
Vserver: Cluster
Destination: 172.31.112.173
Time of Test: 4/25/2016 10:38:32
MB/s: 39.8192
cluster1::network test-link*> show
Node Vserver Destination Time of Test MB/s
----------------- ----------------- --------------- ------------------- ------------
node2 Cluster 172.31.112.173 4/25/2016 10:38:32 39.8192
Give documentation feedback