storage disk error show
Display disk component and array LUN configuration errors.
Availability: This command is available to cluster administrators at the admin privilege level.
Description
The storage disk error show command displays disk component and array LUN configuration errors.
Parameters
- { [-fields <fieldname>, ...]
 - If you specify the -fields <fieldname>, ... parameter, the command output also includes the specified field or fields. You can use '-fields ?' to display the fields to specify.
 - | [-instance ]}
 - If you specify the -instance parameter, the command displays detailed information about all fields.
 - [-uid <text>] - UID
 - Displays the error information of the disk whose unique ID matches the value you specify. A disk unique identifier has the form: 20000000:875D4C32:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000
 - [-array-name <array name>] - Array Name
 - Displays the errors of the storage array whose name you specified.
 - [-node {<nodename>|local}] - Controller Name
 - Displays the error information for the disks on the clustered node whose name you specified.
 - [-disk <disk path name>] - Disk
 - Displays detailed error information about the disk you specified.
 - [-serial-number <text>] - Serial Number
 - Displays the error information for the disk whose serial number you specified.
 - [-error-id <integer>, ...] - Error ID
 - Displays the error information for the disks whose Error IDs match IDs you specified.
 - [-error-type {onepath|onedomain|control|foreign|toobig|toosmall|invalidblocksize|targetasymmap|deviceassymmap|failovermisconfig|unknown|lenovo|fwdownrev|qualfail|diskfail|notallflashdisk}, ...] - Error Type
 - Displays all disk errors of the error types you specified, grouped by type.
- onepath = The array LUN is accessible only via a single path.
 - onedomain = The array LUN is accessible only via a single fault domain.
 - control = The array LUN cannot be used because it is a control device.
 - foreign = The array LUN is marked as foreign and has some external SCSI reservations other than those from Data ONTAP.
 - toobig = The array LUN exceeds the maximum array LUN size that Data ONTAP supports.
 - toosmall = The array LUN is less than the minimum array LUN size that Data ONTAP supports.
 - invalidblocksize = The array LUN is not a valid block size.
 - targetasymmap = The array LUN is presented more than once on a single target port.
 - deviceassymmap = The array LUN is presented with multiple IDs.
 - failovermisconfig = The array LUN is configured with inconsistent failover methods.
 - unknown = The array LUN from a storage array that is not supported by this version of Data ONTAP.
 - lenovo = A SAN front-end LUN from one Data ONTAP system that is presented as external storage to another Data ONTAP system.
 - fwdownrev = The disk firmware is a down version.
 - qualfail = The disk is not supported.
 - diskfail = The disk is in a failed state.
 - notallflashdisk = The disk does not match the All-Flash Optimized personality of the system.
 
 
Examples
The following example displays configuration errors seen in the system:
cluster1::> storage disk error show
Disk             Error Type        Error Text
---------------- ----------------- --------------------------------------------
1.02.0           qualfail          This disk failed dynamic disk qualification. Update the Disk Qaulification Package.
Give documentation feedback