storage shelf acp show
Show connectivity information
Availability: This command is available to cluster administrators at the admin privilege level.
Description
Displays information about the ACP connectivity on each node
Parameters
- { [-fields <fieldname>, ...]
 - If you specify the -fields <field-name>", ... parameter, the command output also includes the specified field or fields. You can use '-fields ?' to display the fields to specify.
 - | [-errors ]
 - If you specify the -errors parameter, the command displays detailed information about all modules with errors.
 - | [-instance ]}
 - If you specify the -instance parameter, the command displays detailed information about all fields.
 - [-node {<nodename>|local}] - Node
 - Selects the nodes that match this parameter value.
 - [-is-enabled {true|false}] - Is Enabled?
 - Selects the nodes that are enabled or disabled.
 - [-port <text>] - Port
 - Selects the nodes that match the specified port on which ACP is configured.
 - [-address <IP Address>] - IP Address
 - Selects the nodes with the specified IP address.
 - [-subnet <IP Address>] - Subnet
 - Selects the nodes with the specified subnet.
 - [-netmask <IP Address>] - Netmask
 - Selects the nodes with the specifed netmask.
 - [-connection-status {no-connectivity|partial-connectivity|full-connectivity|additional-connectivity|unknown-connectivity|not-available|connection-disabled}] - Connection Status
 - Selects the nodes with the specified connection status.
 - [-error-id <integer>] - Error ID
 - Selects the node with the specified error ID.
 - [-error-type {No-Error|Connection-Issue|Connection-Activity|Module-Error|Shelf-Error}] - Error Type
 - The error type, in case of a connection error.
 - [-error-severity {unknown|notice|warning|error|critical}] - Error Severity
 - The error severity, in case of a connection error.
 - [-error-text <text>] - Error Text
 - Selects the node with the specified error text.
 - [-corrective-action <text>] - Corrective Action
 - Selects the node with the specified corrective action.
 - [-channel {unknown|out-of-band|in-band}] - Channel
 - Selects the nodes that has channel configured out-of-band or in-band.
 
Examples
The following example displays ACP connectivity on each node (in-band):
fas2750-2n-rtp-1::> storage shelf acp show
    Node                Channel                Connectivity
        ------------------  --------------------   ----------------------
    fas2750-rtp-1a      in-band                active
    fas2750-rtp-1b      in-band                active
    2 entries were displayed.
The following example displays ACP connectivity on each node (out of band):
fas2750-2n-rtp-1::> storage shelf acp show
        Node                Channel                Connectivity
    ------------------  --------------------   ----------------------
    fas2750-rtp-1a      out-of-band            full-connectivity
    fas2750-rtp-1b      out-of-band            full-connectivity
    2 entries were displayed.
The following example displays the -instance output of the storage acp show (in-band) command. Use this command to display details on connectivity and configuration.
fas2750-2n-rtp-1::> storage shelf acp show -instance
                 Node: fas2750-rtp-1a
          Channel: in-band
        Enable Status: true
    Connection Status: active
                 Node: fas2750-rtp-1b
          Channel: in-band
        Enable Status: true
    Connection Status: active
    2 entries were displayed.
The following example displays the -instance output of the storage acp show (out-of-band) command. Use this command to display details on connectivity and configuration.
fas2750-2n-rtp-1::> storage shelf acp show -instance
         Node: fas2750-rtp-1a
          Channel: out-of-band
    Enable Status: true
         Port: e0P
       IP Address: 192.168.1.74
           Subnet: 192.168.0.1
          Netmask: 255.255.252.0
    Connection Status: full-connectivity
         Node: fas2750-rtp-1b
          Channel: out-of-band
    Enable Status: true
         Port: e0P
       IP Address: 192.168.1.75
           Subnet: 192.168.0.1
          Netmask: 255.255.252.0
    Connection Status: full-connectivity
    2 entries were displayed.
Give documentation feedback