Skip to main content

storage bridge add

Add a bridge for monitoring

Availability: This command is available to cluster administrators at the admin privilege level.

Description

The storage bridge add command enables you to add FC-to-SAS bridges for SNMP monitoring in a MetroCluster configuration.

Parameters

-address <IP Address> - Bridge Management Port IP Address
This parameter specifies the IP address of the bridge that is being added for monitoring.
[-snmp-community <text>] - SNMP Community
This parameter specifies the SNMP community set on the bridge that is being added for monitoring.
[-veto-backend-fabric-check {true|false}] - Veto Backend Fabric Check (privilege: advanced)
If specified, the storage bridge add command will not check if the bridge is present in the MetroCluster's backend fabric. By default, it does not let you add bridges that are not present.

Examples

The following command adds a bridge with IP address '10.226.197.16' for monitoring:

    cluster1::> storage bridge add -address 10.226.197.16

cluster1::> storage bridge show
Is Monitor
Bridge Symbolic Name Vendor Model Bridge WWN Monitored Status
---------- ------------- ------- --------- ---------------- --------- -------
ATTO_10.226.197.16
Bridge Number 16
Atto FibreBridge 6500N
2000001086603824 true -
ATTO_FibreBridge6500N_2
Not Set Atto FibreBridge 6500N
20000010866037e8 false -
ATTO_FibreBridge6500N_3
Not Set Atto FibreBridge 6500N
2000001086609e0e false -
ATTO_FibreBridge6500N_4
Not Set Atto FibreBridge 6500N
2000001086609c06 false -
4 entries were displayed.