lun transition 7-mode show
Display the 7-Mode LUN Inventory
Availability: This command is available to cluster administrators at the advanced privilege level.
Description
The lun transition 7-mode show command displays information about LUNs copied from a Data ONTAP 7-Mode system. If no parameters are specified, the command displays the following information about all 7-Mode LUNs:
Vserver name
LUN path
Operating system type
Size
Whether or not the LUN has been transitioned to clustered Data ONTAP
Parameters
- { [-fields <fieldname>, ...]
- If you specify the -fields <fieldname>, ... parameter, the command output also includes the specified field or fields. You can use '-fields ?' to display the fields to specify.
- | [-instance ]}
- If you specify the -instance parameter, the command displays detailed information about all fields.
- [-vserver <Vserver Name>] - Vserver Name
- Selects the 7-Mode LUNs in the specified Vserver.
- [-path <path>] - LUN Path
- Selects the 7-Mode LUNs with the specified path.
- [-volume <volume name>] - Volume Name
- Selects the 7-Mode LUNs that match the specified volume.
- [-ostype {vmware|hyper_v|windows_2008|windows_gpt|windows|linux|xen|solaris|solaris_efi|hpux|aix|netware|openvms}] - OS Type
- Selects the 7-Mode LUNs that match the specified operating system type.
- [-size <size>] - LUN Size
- Selects the 7-Mode LUNs that match the specified size.
- [-prefix-size <size>] - Prefix Stream Size
- Selects the 7-Mode LUNs that match the specified prefix stream size.
- [-suffix-size <size>] - Suffix Stream Size
- Selects the 7-Mode LUNs that match the specified suffix stream size.
- [-serial <text>] - Serial Number
- Selects the 7-Mode LUNs that match the specified serial number for clustered Data ONTAP. LUNs where is-transitioned is false do not have a serial number assigned for clustered Data ONTAP.
- [-uuid <UUID>] - UUID
- Selects the 7-Mode LUNs that match the specified UUID for clustered Data ONTAP. LUNs where is-transitioned is false do not have a UUID assigned for clustered Data ONTAP.
- [-serial-7-mode <text>] - 7-mode Serial Number
- Selects the 7-Mode LUNs that match the specified serial number from 7-Mode.
- [-is-transitioned {true|false}] - Transition Complete
- Selects the 7-Mode LUNs that match the specified transition state. LUNs where this value is true have been transitioned and are available to be mapped for client access. LUNs where this value is false have not yet been transitioned and may not be mapped.
- [-vserver-uuid <UUID>] - Vserver UUID
- Selects the 7-Mode LUNs that match the specified Vserver UUID.
- [-node <nodename>] - Node
- Selects the 7-Mode LUNs that match the specified node name.
Examples
The following example displays a summary of all 7-Mode LUNs for the volume vol1 in a Vserver named vs1:
cluster1::*> lun transition 7-mode show -vserver vs1 -volume vol1
Vserver Path Type Size Transitioned
--------- ---------------------------- -------- ------ ------------
vs1 /vol/vol1/lun1 linux 10MB false
/vol/vol1/lun2 linux 500MB true
/vol/vol1/lun3 linux 500MB true
8 entries were displayed.
The following example displays detailed information for the 7-Mode LUN /vol/vol1/lun2 in a Vserver named vs1:
cluster1::*> lun transition 7-mode show -vserver vs1 -path /vol/vol1/lun2
Vserver Name: vs1
LUN Path: /vol/vol1/lun2
Volume Name: vol1
OS Type: linux
LUN Size: 500MB
Prefix Stream Size: 0
Suffix Stream Size: 0
Serial Number: BCVvv$DLZu8g
UUID: f53d603b-9663-4567-9680-95c1a9cc6d9e
7-mode Serial Number: C4eqKotPI8Ui
Transition Complete: true
Vserver UUID: be4cc135-163f-11e3-931f-123478563412
Node: cluster-01
Give documentation feedback