Skip to main content

metrocluster check lif show

Show results of MetroCluster check results for the data LIFs

Availability: This command is available to cluster administrators at the admin privilege level.

Description

The metrocluster check lif show command displays the LIF placement failures in the MetroCluster configuration.

The command verifies the following aspects of the LIF placements of all the data LIFs in Metrocluster:

  • lif-placed-on-dr-node: This check verifies that the LIF is placed on DR partner node.

  • port-selection: This check verifies that the LIF is placed on correct port.

The LIF placement failures are mostly fabric/network connectivity issues that require manual intervention. Once the connectivity issues are resolved manually, the admin is expected to run metrocluster check lif repair-placement command to resolve the LIF placement issues for the sync source Vserver.

Additional information about the warnings (if any) and recovery steps can be viewed by running the command with the -instance option.

Parameters

{ [-fields <fieldname>, ...]
If you specify the -fields <fieldname>, ... parameter, the command output also includes the specified field or fields. You can use '-fields ?' to display the fields to specify.
| [-instance ]}
If you specify the -instance parameter, the command displays detailed information about all fields.
[-cluster <Cluster name>] - Name of the Cluster
This is the name of the cluster the LIF belongs to. If this parameter is specified, only rows with this cluster will be displayed.
[-vserver <text>] - Name of the Vserver
This is the name of the Vserver in the MetroCluster configuration
[-lif <lif-name>] - Name of the Lif
This is the name of the LIF.
[-check <MetroCluster LIF placement Check>] - Description
This is the type of the check performed. If this parameter is specified, only rows with this check will be displayed.
[-result {ok|warning|not-run|not-applicable}] - Result of the Check
This is the result of the check performed. If this parameter is specified, only rows with this result will be displayed.
[-additional-info <text>] - Additional Information/Recovery Steps
This is additional information about the check. This field has more information and recovery steps for the warning. If this parameter is specified, only rows with this additional info will be displayed.

Examples

The following example shows the execution of the command in a MetroCluster configuration with two nodes per cluster:

clusA::>metrocluster check  lif show
Cluster Vserver LIF Check Result
------------------- ----------- ----------- ---------------------- ------
ClusA vs1 a_data1 lif-placed-on-dr-node ok
port-selection ok
a_data1_inet6
lif-placed-on-dr-node ok
port-selection ok
ClusA vs2-mc b_data1 lif-placed-on-dr-node ok
port-selection warning
b_data1_inet6
lif-placed-on-dr-node ok
port-selection warning
ClusB vs1-mc a_data1 lif-placed-on-dr-node warning
port-selection ok
a_data1_inet6
lif-placed-on-dr-node warning
port-selection ok
ClusB vs2 b_data1 lif-placed-on-dr-node ok
port-selection ok
b_data1_inet6
lif-placed-on-dr-node ok
port-selection ok
16 entries were displayed.