storage path show
Display a list of paths to attached arrays.
Description
The storage path show command displays path based statistics. The default command shows:
Node name
Initiator port
Target port
Target IQN
TPGN
Port speeds
Path I/O in Kbytes/sec
IOPs
Parameters
- { [-fields <fieldname>, ...]
 - If you specify the -fields <fieldname>, ... parameter, the command output also includes the specified field or fields. You can use '-fields ?' to display the fields to specify.
 - | [-array ]
 - Using this option displays:
Array name
Target port
Target IQN
Target I/O in Kbytes/sec
Target side switch port
Path I/O in Kbytes/sec
Initiator side switch port
Initiator I/O in Kbytes/sec
Initiator port
 - | [-by-target ]
 - Using this option displays the same information as the array option, but grouped by target port.
 - | [-detail ]
 - Using this option displays the same information as the array and by-target options, but adds the following:
Target IOPs
Target LUNs
Path IOPs
Path errors
Path quality
Path LUNs
Initiator IOPs
Initiator LUNs
 - | [-switch ]
 - Using this option adds switch port information to the default display.
 - | [-instance ]}
 - If you specify the -instance parameter, the command displays detailed information about all fields.
 - [-node {<nodename>|local}] - Controller name
 - The name of the clustered node for which information is being displayed.
 - [-array-name <array name>] - Array Name
 - Name of the storage array that is connected to the cluster.
 - [-target-wwpn <text>] - Target Port
 - Target World Wide Port Name. Port on the storage array that is being used.
 - [-initiator <text>] - Initiator Port
 - Initiator port that the clustered node uses.
 - [-initiator-side-switch-port <text>] - Initiator Side Switch Port
 - Switch port connected to the clustered node.
 - [-tpgn <integer>] - Target Port Group Number
 - TPGN refers to the target port group to which the target port belongs. A target port group is a set of target ports which share the same LUN access characteristics and failover behaviors.
 - [-port-speed <text>] - Port Speed
 - Port Speed of the specified port.
 - [-path-io-kbps <integer>] - Kbytes of I/O per second on Path (Rolling Average)
 - Rolling average of I/O per second on the path.
 - [-path-iops <integer>] - Number of IOPS on Path (Rolling Average)
 - Rolling average of Kbytes of I/O per second on the path
 - [-initiator-io-kbps <integer>] - Kbytes of I/O per second on Initiator (Rolling Average)
 - Rolling average of I/O per second on the initiator port.
 - [-initiator-iops <integer>] - Number of IOPS on Initiator (Rolling Average)
 - Rolling average of Kbytes of I/O per second on the initiator port.
 - [-target-io-kbps <integer>] - Kbytes of I/O per second to Target (Rolling Average)
 - Rolling average of I/O per second on the target port.
 - [-target-iops <integer>] - Number of IOPS to Target (Rolling Average)
 - Rolling average of Kbytes of I/O per second on the target port.
 - [-target-side-switch-port <text>] - Target Side Switch Port
 - Switch port connected to the array.
 - [-path-link-errors <integer>] - Link Error count on path
 - Fibre Channel link error count.
 - [-path-quality <integer>] - Percentage of weighted error threshold
 - A number representing the threshold of errors that is allowed on the path. Path quality is a weighted error value. When the error weight of a path exceeds the threshold, I/O is routed to a different path.
 - [-path-lun-in-use-count <integer>] - Number of LUNs in the in-use state on this path
 - Number of LUNs on this path.
 - [-initiator-lun-in-use-count <integer>] - Number of LUNs in the in-use state on this initiator
 - Number of LUNs on this initiator.
 - [-target-lun-in-use-count <integer>] - Number of LUNs in the in-use state on this target
 - Number of LUNs on this target.
 - [-vmdisk-device-id <integer>] - Virtual disk device ID
 - Common device identifier, shared by a VM and its hypervisor, of a virtual disk. On ESX servers, this is the Disk ID component of a virtual device node, with a value of 0 to 15.
 - [-path-failure-threshold <integer>] - Max number of path failures acceptable in wait-duration
 - The path failure count, exceeding this value within wait duration will quiesce the path.
 - [-wait-duration <integer>] - Wait Duration in minutes
 - The time duration(minutes) in which path is monitored for path failures.
 
Examples
The following example shows the default display.
vbv3170f2a::> storage path show
                                                                                Path I/O
Node                   Initiator  Array Target Port          TPGN    Speed        (KB/s)          IOPS
---------------------  ---------  -----------------------  ------  -------  ------------  ------------
vbv3170f2a-01          0b         50001fe1500a866c              2   2 Gb/S             6             2
vbv3170f2a-01          0b         50001fe1500a866d              2   2 Gb/S             0             0
vbv3170f2a-01          0c         50001fe1500a866e              4   4 Gb/S             0             0
vbv3170f2b-03          0a         50001fe1500a866d              1   2 Gb/S             3             1
vbv3170f2b-03          0c         50001fe1500a866f              4   4 Gb/S             3             1
5 entries were displayed.
The following example shows how the information is displayed with the array option.
vnv3070f20b::> storage path show -array
Node: vnv3070f20b
Target I/O   Target Side   Path I/O  Initiator Side Initiator I/O Initiator
Array Name   Target Port   (KB/s)  Switch Port  (KB/s)  Switch Port (KB/s)   Port
---------------- ---------------- ------------ -------------------- ------------
HITACHI_DF600F_1 50060e80004291c0  0  vnbr3850s5:12    0  vnbr3850s4:4  3   0a
                 50060e80004291c2  0  vnci9124s54:1-22 0  vnci9124s54:1-6  26   0c
IBM_1722_1       200600a0b819e16f  3  vnbr3850s5:15   3   vnbr3850s4:4   3   0a
                 200700a0b819e16f  26 vnci9124s54:1-24  26  vnci9124s54:1-6   26   0c
4 entries were displayed.
The following example shows how the information is displayed when grouped by target.
vnv3070f20b::> storage path show -by-target
Node: vnv3070f20b
Array Name: HITACHI_DF600F_1
 Target I/O  Target Side     Path I/0      Initiator Side Initiator I/O Initiator
Target Port   (KB/s)   Switch Port  (KB/s)   Switch Port   (KB/s)      Port
---------------- ------------ -------------------- ------------ -----------------
50060e80004291c0   0  vnbr3850s5:12     0   vnbr3850s4:4     3        0a
50060e80004291c2   0  vnci9124s54:1-22  0   vnci9124s54:1-6    26        0c
Node: vnv3070f20b
Array Name: IBM_1722_1
                   Target I/O          Target Side     Path I/0       Initiator Side Initiator I/O Initiator
Target Port            (KB/s)          Switch Port       (KB/s)    Switch Port      (KB/s) Port
---------------- ------------ -------------------- ------------ -------------------- ------------
200600a0b819e16f   3      vnbr3850s5:15     3    vnbr3850s4:4  3    0a
200700a0b819e16f   26     vnci9124s54:1-24    26  vnci9124s54:1-6    26     0c
4 entries were displayed.
The following example shows how the information is displayed with the switch option.
vbv3170f2b::> storage path show -switch
Target Side          Initiator Side                             Path I/O
Node            Initiator  Array Target Port   Switch Port      Switch Port      TPGN   Speed    (KB/s)   IOPS
---------------------  ---------  -----------------------  -------------------- --------------------  ------  -
vbv3170f2a-01   0b         50001fe1500a866c    vbbr300s1:6      vbbr300s1:2      2      2 Gb/S    9       3
vbv3170f2a-01   0b         50001fe1500a866d    vbbr300s1:7      vbbr300s1:2      2      2 Gb/S    0       0
vbv3170f2a-01   0c         50001fe1500a866e    vbci9124s2:1-7   vbci9124s2:1-3   4      4 Gb/S    0       0
vbv3170f2b-03   0a         50001fe1500a866d    vbbr300s1:7      vbbr300s1:3      1      2 Gb/S    4       1
vbv3170f2b-03   0c         50001fe1500a866f    vbci9124s2:1-8   vbci9124s2:1-4   4      4 Gb/S    4       1
5 entries were displayed.