Skip to main content

storage shelf show

Display a list of storage shelves

Availability: This command is available to cluster administrators at the admin privilege level.

Description

The storage shelf show command displays information about all the storage shelves in the storage system. If no parameters are specified, the default command displays the following information about the storage shelves:

  • Shelf Name

  • Shelf ID

  • Serial Number

  • Model

  • Module Type

  • Status

To display detailed profile information about a single storage shelf, use the -shelf parameter.

Parameters

{ [-fields <fieldname>, ...]
Displays the specified fields for all the storage shelves, in column style output.
| [-bay ]
Displays the following details about the disk bays in the storage shelf:
  • The unique positional identifier of the disk bay

  • Whether a disk drive is installed in the bay

  • Bay type

  • Operational status of the disk bay

| [-connectivity ]
Displays the following details about the connectivity from the node to the storage shelf:
  • Node name

  • Initiator side switch port

  • Target side switch port

  • World wide port name

  • Target Port Group Number (TPGN)

| [-cooling ]
Displays the following details about the cooling elements and temperature sensors of the storage shelf:
  • Element ID of the cooling fan

  • The current speed of the cooling fan in revolutions per minute (rpm)

  • Operational status of the cooling fan

  • Sensor ID of the temperature sensor element

  • Temperature at the sensor in degrees Celsius

  • Whether the current temperature at the sensor is the ambient temperature

  • Low critical threshold value for the temperature sensor

  • Low warning threshold value for the temperature sensor

  • High critical threshold value for the temperature sensor

  • High warning threshold value for the temperature sensor

  • Operational status for the temperature sensor

| [-errors ]
Displays the following error status information about the storage shelves which have errors:
  • Error type

  • Error description

| [-module ]
Displays the following details about the I/O modules attached to the storage shelf:
  • Module ID

  • Module Part number

  • Serial number of the Enclosure Services Controller Electronics element

  • Whether monitoring is enabled on this module

  • Whether this module is the SAS expander master module

  • Whether this module is the element reporting

  • Version of the firmware installed on the module

  • Latest firmware revision

  • Number of times, since last boot, that this module has been swapped

  • Operational status of the module

| [-port ]
Displays the following details about the storage shelf ports:
  • Expander phy element identifier

  • SAS shelf port type

  • World Wide Port Name of the SAS port

  • Operational physical link rate of the SAS port in Gb/s

  • Negotiated physical link rate of the SAS port in Gb/s

  • Power status of the SAS port

  • Status of the SAS port

  • Fibre Channel shelf port ID

  • Fibre Channel shelf port type

  • Fibre Channel shelf port status

| [-power ]
Displays the following details about the power supplies, voltage sensors and current sensors of the storage shelf:
  • Power Supply Unit (PSU) number

  • PSU type

  • PSU part number

  • PSU serial number

  • PSU power rating in watts

  • PSU crest factor

  • Power drawn from the PSU in watts

  • Whether the PSU can be reset via software control

  • Whether the auto power reset of the PSU is enabled

  • PSU firmware revision

  • Operational status of the PSU

  • Voltage sensor number

  • Voltage detected by the voltage sensor, in volts (V)

  • Operational status of the voltage sensor

  • Current sensor number

  • Current detected by the current sensor, in milliamps (mA)

  • Operational status of the current sensor

| [-instance ]}
Displays expanded information about all the storage shelves in the system.
[-node {<nodename>|local}] - Node
Displays information only about the storage shelves that are attached to the node you specify.
[-shelf <text>] - Shelf Name
Displays information only about the storage shelves that match the names you specify.
[-shelf-uid <text>] - Shelf UID
Displays information only about the storage shelf that matches the shelf UID you specify. Example: 50:05:0c:c0:02:10:64:26
[-stack-id {<integer>|-}] - Stack ID
Displays information only about the storage shelves that are attached to the stack that matches the stack ID you specify
[-shelf-id <text>] - Shelf ID
Displays information only about the storage shelves that match the shelf ID you specify.
[-module-type {unknown|atfcx|esh4|iom3|iom6|iom6e|iom12|iom12e|iom12f|psm3e}] - Shelf Module Type
Displays information only about the storage shelves that match the module-type you specify.
[-connection-type {unknown|fc|sas|nvme}] - Shelf Connection Type
Displays information only about the storage shelves that match the connection type you specify. Example: FC or SAS.
[-is-local-attach {true|false}] - Is the Shelf Local to This Cluster?
Displays information only about the storage shelves that are local (TRUE) or remote (FALSE) to this cluster.
[-vendor <text>] - Shelf Vendor
Displays information only about the storage shelves that match the vendor you specify.
[-product-id <text>] - Shelf Product Identification
Displays information only about the storage shelves that match the product ID you specify.
[-serial-number <text>] - Shelf Serial Number
Displays information only about the storage shelf that matches the serial number you specify.
[-disk-count {<integer>|-}] - Disk Count
Displays information only about the storage shelves that have the disk count you specify.
[-state {unknown|no-status|init-required|online|offline|missing}] - Shelf State
Displays information only about the storage shelves that are in the state you specify.
[-op-status {unknown|normal|warning|error|critical|standby-power}] - Shelf Operational Status
Displays information only about the storage shelves that are currently operating under the status condition you specify.
[-bay-id {<integer>|-}, ...] - Bay ID
Displays information only about the storage shelves that have bays that match the bay ID you specify.
[-bay-type {unknown|single-disk|multi-lun}, ...] - Bay Type
Displays information only about the storage shelves that have bays that match the type of bay you specify.
[-bay-has-disk {true|false}, ...] - Bay Has Disk
Displays information only about the storage shelves that have bays with disk drives inserted in them (true) or empty bays (false).
[-bay-op-status {unknown|normal|error}, ...] - Bay Operational Status
Displays information only about the storage shelves that have bays that match the operational state you specify.
[-controller {<nodename>|local}, ...] - Controller Name
Displays information only about the storage shelves that are connected to the node you specify.
[-controller-uuid <text>, ...] - Controller UUID
Displays information only about the storage shelves that are connected to the node UUID you specify.
[-initiator <text>, ...] - Initiator
Displays information only about the storage shelves that are visible to the initiator you specify.
[-initiator-wwpn <text>, ...] - Initiator WWPN
Displays information only about the storage shelves that are visible to the initiator WWPN you specify.
[-initiator-side-switch-port <text>, ...] - Initiator Side Switch Port
Displays information only about the storage shelves that are visible to an initiator connected to the switch port you specify.
[-target-side-switch-port <text>, ...] - Target Side Switch Port
Displays information only about the storage shelves visible on target ports identified by the switch port to which they are connected.
[-target-port <text>, ...] - Target Port
Displays information only about the storage shelves visible on the specified target ports identified by their World Wide Port Name (WWPN).
[-tpgn {<integer>|-}, ...] - Target Port Group Number
Displays information only about the storage shelves that belong to the Target Port Group Name (TPGN) you specify.
[-port-speed {<integer>|-}, ...] - Port Speed
Displays information only about the storage shelves with ports that match the port speed you specify.
[-io-kbps {<integer>|-}, ...] - Kbytes/sec on Storage Shelf
Displays information only about the storage shelves visible to an initiator that has executed I/O at the throughput you specify.
[-iops {<integer>|-}, ...] - Number IOPS per Second on Storage Shelf
Displays information only about the storage shelves visible to an initiator that has executed the number of IOPs you specify.
[-current-sensor-id {<integer>|-}, ...] - Current Sensor ID
Displays information only about the storage shelves with current sensor that matches the current sensor ID you specify.
[-current-sensor-location <text>, ...] - Current Sensor Location
Displays information only about the storage shelves with current sensors installed at the location you specify.
[-current-sensor-reading {<integer>|-}, ...] - Current Sensor Reading
Displays information only about the storage shelves with current sensors that match the current reading you specify.
[-current-op-status {unknown|normal|over-current-critical|under-current-critical|not-supported|not-installed}, ...] - Operational Status
Displays information only about the storage shelves with current sensors that match the operational status you specify.
[-fan-id {<integer>|-}, ...] - Fan ID
Displays information only about the storage shelves with a cooling fans that match the fan IDs you specify.
[-fan-location <text>, ...] - Fan Location
Displays information only about the storage shelves with cooling fans installed.
[-fan-rpm {<integer>|-}, ...] - Fan Rotation Per Minute
Displays information only about the storage shelves with cooling fans that match the rpm you specify.
[-fan-op-status {unknown|normal|off|error|not-supported|not-installed}, ...] - Fan Operational Status
Displays information only about the storage shelves with cooling fans that match the operational status you specify.
[-module-id <text>, ...] - Module ID
Displays information only about the storage shelves with an I/O module that matches the module ID you specify.
[-module-location <text>, ...] - Module Location
Displays information only about the storage shelves with I/O modules in the specified shelf module slots.
[-module-part-number <text>, ...] - Module Part Number
Displays information only about the storage shelves with I/O modules that match the module part numbers you specify.
[-is-sas-master-module {true|false}, ...] - Is SAS Expander Master Module?
Displays information only about the storage shelves with a SAS master I/O module (true) or an I/O module that is not a SAS master (false). This parameter applies only to SAS shelves.
[-is-monitor-active {true|false}, ...] - Is Monitor Active?
Displays information only about the storage shelves whose monitoring is enabled (true) or disabled (false).
[-enclosure-type <text>, ...] - Module Enclosure Type
Displays information only about the storage shelves that match the enclosure types you specify.
[-es-serial-number <text>, ...] - ES Electronics Element Serial Number
Displays information only about the storage shelves with I/O modules that match the electronics serial numbers you specify.
[-module-fru-id <text>, ...] - Field Replaceable Unit ID
Displays information only about the storage shelves with I/O modules that match the field replaceable unit (FRU) IDs you specify.
[-module-is-reporting-element {true|false}, ...] - Is Reporting Element?
Displays information only about the storage shelves with element reporting I/O modules (true) or not (false).
[-module-fw-revision <text>, ...] - Firmware Revision
Displays information only about the storage shelves with I/O modules that match the firmware revision you specify.
[-module-latest-fw-revision <text>, ...] - Latest Firmware Revision
Displays information only about the storage shelves with I/O modules that match the latest firmware revision you specify.
[-module-fw-progress {not-available|ready|in-progress|failed}, ...] - Module Firmware Progress
Displays information only about the storage shelves with I/O modules that match the specified firmware update progress.
[-module-swap-count {<integer>|-}, ...] - Module Swap Count
Displays information only about the storage shelves whose I/O modules have been swapped the specified number of times.
[-module-op-status {unknown|normal|warning|error}, ...] - Module Operational Status
Displays information only about the storage shelves with I/O modules that match the operational status you specify.
[-sas-port-id <text>, ...] - Port ID
Displays information only about the storage shelves with SAS Ports that match the port IDs you specify.
[-sas-port-type {unknown|circle|square|sil|disk|in|out|unused|host|dcm|aux1|aux2|hi_ho|a_to_b|b_to_a}, ...] - Port Type
Displays information only about the storage shelves with SAS Ports that match the SAS port type you specify.
[-sas-port-wwpn <text>, ...] - Port World Wide Port Name
Displays information only about the storage shelves with SAS Ports that match the World Wide Port Names you specify.
[-sas-port-speed <text>, ...] - Port Speed
Displays information only about the storage shelves with SAS Ports that match the port speed you specify.
[-sas-negotiated-port-speed <text>, ...] - Negotiated Port Speed
Displays information only about the storage shelves with SAS Ports that match the negotiated port speed you specify.
[-sas-port-power-status <text>, ...] - Port Power Status
Displays information only about the storage shelves with SAS Ports that match the power status you specify.
[-sas-port-op-status {error|normal|off|unknown|byp-bad-term|bad-zone-recovery|byp_clk_thr|byp_comma_los|byp_crc_brst_thr|byp_data_timeout|byp_drv_fault|byp_drv_pcycle|byp_drv_pwr|byp_drv_self|byp_gen|byp_init|byp_lip_brst_thr|byp_lip_f8|byp_lip_rate_thr|byp_lipf7|byp_ltbi|byp_man|byp_no_drive|byp_osc|byp_other_thr|byp_rec_los|byp_rport|byp_stall_thr|byp_wrd_brst_thr|byp_wrd_rate_thr|byp_xmit_fault|diag_transmit|inserted|loopback|status_unknown|warn_high_clk_delta|warn_high_crc_rate|warn_high_lip|warn_high_wrd_rate|term|phy_dis_clk_fault|phy_dis_crc_err|phy_dis_crc_err_burst|phy_dis_disparity|phy_dis_disparity_burst|phy_dis_emulate_reserve|phy_dis_inval_dword|phy_dis_inval_dword_burst|phy_dis_loss_dword|phy_dis_loss_dword_burst|phy_dis_man_smp|phy_dis_manual|phy_dis_mirrored|empty|phy_dis_phy_change|phy_dis_phy_change_burst|phy_dis_phy_reset|phy_dis_phy_reset_burst|phy_dis_phy_unused|phy_ena|phy_ena_not_attach|phy_ena_unknown|phy_unknown}, ...] - Port Operational Status
Displays information only about the storage shelves with SAS Ports that match the operational status you specify. Displays information only about the storage shelves with SAS Ports that match the operational status you specify.
[-sas-port-module-id {A|B}, ...] - Port Module ID
Displays information only about the storage shelves with SAS Ports that match the module ID you specify.
[-fc-port-id <text>, ...] - Fibre Channel Port ID
Displays information only about the storage shelves with FC Ports that match the port IDs you specify.
[-fc-port-mode {unknown|circle|square|sil|disk|in|out|unused|host|dcm|aux1|aux2|hi_ho|a_to_b|b_to_a}, ...] - Fibre Channel Port Mode
Displays information only about the storage shelves with FC Ports that match the port modes you specify.
[-fc-port-op-status {error|normal|off|unknown|byp-bad-term|bad-zone-recovery|byp_clk_thr|byp_comma_los|byp_crc_brst_thr|byp_data_timeout|byp_drv_fault|byp_drv_pcycle|byp_drv_pwr|byp_drv_self|byp_gen|byp_init|byp_lip_brst_thr|byp_lip_f8|byp_lip_rate_thr|byp_lipf7|byp_ltbi|byp_man|byp_no_drive|byp_osc|byp_other_thr|byp_rec_los|byp_rport|byp_stall_thr|byp_wrd_brst_thr|byp_wrd_rate_thr|byp_xmit_fault|diag_transmit|inserted|loopback|status_unknown|warn_high_clk_delta|warn_high_crc_rate|warn_high_lip|warn_high_wrd_rate|term|phy_dis_clk_fault|phy_dis_crc_err|phy_dis_crc_err_burst|phy_dis_disparity|phy_dis_disparity_burst|phy_dis_emulate_reserve|phy_dis_inval_dword|phy_dis_inval_dword_burst|phy_dis_loss_dword|phy_dis_loss_dword_burst|phy_dis_man_smp|phy_dis_manual|phy_dis_mirrored|empty|phy_dis_phy_change|phy_dis_phy_change_burst|phy_dis_phy_reset|phy_dis_phy_reset_burst|phy_dis_phy_unused|phy_ena|phy_ena_not_attach|phy_ena_unknown|phy_unknown}, ...] - Fibre Channel Port Operational Status
Displays information only about the storage shelves with FC Ports that match the operational status you specify.
[-psu-id {<integer>|-}, ...] - Power Supply Unit ID
Displays information only about the storage shelves with power supply units (PSU) that match the unit IDs you specify.
[-psu-location <text>, ...] - Power Supply Unit Location
Displays information only about the storage shelves with PSUs that are located at the specified location inside the shelf.
[-psu-type <text>, ...] - Power Supply Unit Type
Displays information only about the storage shelves with PSUs that match the PSU types you specify.
[-psu-part-number <text>, ...] - Power Supply Unit Part Number
Displays information only about the storage shelves with PSUs that match the PSU part number you specify.
[-psu-serial-number <text>, ...] - Power Supply Unit Serial Number
Displays information only about the storage shelves with PSUs that match the PSU serial numbers you specify.
[-psu-reset-capable {true|false}, ...] - Power Supply Unit Reset Capability
Displays information only about the storage shelves with reset capable PSUs (true) or reset incapable PSUs (false).
[-psu-is-enabled {true|false}, ...] - Power Supply Unit Enable/Disable Status
Displays information only about the storage shelves with PSUs that are enabled (true) or disabled (false).
[-psu-fw-version <text>, ...] - Power Supply Unit Firmware Version
Displays information only about the storage shelves with PSUs that have the firmware version you specify.
[-psu-op-status {unknown|normal|error|dc-over-voltage|dc-under-voltage|dc-over-current|over-temperature-error|failed|off|not-supported|not-installed}, ...] - Operational Status
Displays information only about the storage shelves with PSUs that match the operational status you specify.
[-psu-power-rating {<integer>|-}, ...] - Power Supply Power Ratings In Watts
Displays information only about the storage shelves with PSUs that match the power rating you specify.
[-psu-crest-factor {<integer>|-}, ...] - Power Supply Crest Factor
Displays information only about the storage shelves with PSUs that match the crest factor value you specify.
[-psu-power-drawn {<integer>|-}, ...] - Power Drawn From PSU In Watts
Displays information only about the storage shelves with PSUs that match the drawn power you specify.
[-temp-sensor-id {<integer>|-}, ...] - Sensor Name
Displays information only about the storage shelves with temperature sensors that match the sensor IDs you specify.
[-temp-sensor-location <text>, ...] - Sensor Location
Displays information only about the storage shelves with temperature sensors that match the specified sensor locations inside the shelf.
[-temp-sensor-reading {<integer>|-}, ...] - Temperature Reading
Displays information only about the storage shelves with temperature sensors that match the temperature reading you specify.
[-temp-is-ambient {true|false}, ...] - Temperature Reading at Ambient Value
Displays information only about the storage shelves with temperature sensors whose current temperature reading is ambient (true) or not (false).
[-temp-high-critical-threshold {<integer>|-}, ...] - High Critical Threshold
Displays information only about the storage shelves with temperature sensors that match the high critical threshold you specify.
[-temp-high-warning-threshold {<integer>|-}, ...] - High Warning Threshold
Displays information only about the storage shelves with temperature sensors that match the high warning threshold you specify.
[-temp-low-warning-threshold {<integer>|-}, ...] - Low Warning Threshold
Displays information only about the storage shelves with temperature sensors that match the low warning threshold you specify.
[-temp-low-critical-threshold {<integer>|-}, ...] - Low Critical Threshold
Displays information only about the storage shelves with temperature sensors that match the low critical threshold you specify.
[-temp-op-status {unknown|normal|under-temperature|over-temperature|error|not-supported|not-installed}, ...] - Operational Status
Displays information only about the storage shelves with temperature sensors that match the operational status you specify.
[-voltage-sensor-id {<integer>|-}, ...] - Voltage Sensor ID
Displays information only about the storage shelves with voltage sens- ors that match the sensor IDs you specify.
[-voltage-sensor-location <text>, ...] - Voltage Sensor Location
Displays information only about the storage shelves with voltage sens- ors that match the specified sensor locations inside the shelf.
[-voltage-sensor-reading <text>, ...] - Voltage Current Reading
Displays information only about the storage shelves with voltage sens- ors that match the voltage reading you specify.
[-voltage-op-status {unknown|normal|over-voltage-critical|under-voltage-critical|not-supported|not-installed|not-recoverable}, ...] - Operational Status
Displays information only about the storage shelves with voltage sens- ors that match the operational status you specify.
[-error-type {unknown|acpp|bay|configuration|current|disk|internal|fan|module|port|power|temperature|voltage}, ...] - Error Type
Displays information only about the storage shelves with errors that match the error type you specify.
[-error-severity {unknown|notice|warning|error|critical}, ...] - Error Severity
Displays information only about the storage shelves with errors that match the error severity you specify.

Examples

The following example displays information about all storage shelves:

    cluster1::> storage shelf show

Module Operational
Shelf Name Shelf ID Serial Number Model Type Status
----------------- -------- --------------- ----------- ------ -----------
1.1 1 6000832415 DS2246 IOM6 Critical
1.2 2 6000647652 DS2246 IOM6 Normal
1.3 3 6000003844 DS2246 IOM6 Normal
1.4 4 SHJ000000013A9E DS4246 IOM6 Normal
1.5 5 SHJ000000013A84 DS4246 IOM6 Normal
1.6 6 6000005555 DS2246 IOM6 Normal
6 entries were displayed.

cluster1::>

The following example displays expanded information about a storage shelf named 1.2:

    cluster1::> storage shelf show -shelf 1.2 -instance

Shelf Name: 1.2
Stack ID: 1
Shelf ID: 2
Shelf UID: 50:0a:09:80:01:b9:75:41
Serial Number: 6000647652
Module Type: IOM6
Model: DS2246
Shelf Vendor: NETAPP
Disk Count: 12
Connection Type: SAS
Shelf State: Online
Status: Normal


Modules: Module is
Monitor Is Reporting FW Update Latest Swap Operational Module
ID Part No. ES Serial No. is Active Master Element Progress FW Rev. FW Rev. Count Status Location
--- ------------ --------------- --------- ------ --------- ------------- ------- ------- ----- -----------
a 111-00190+A0 8006437891 true false false not-available 0191 - 0 normal rear of the shelf at the top left
b 111-00190+A0 8006435180 true true true not-available 0191 - 0 normal rear of the shelf at the top right

Paths:
Speed
Controller Initiator Initiator Side Switch Port Target Side Switch Port Target Port TPGN Gb/s I/O KB/s IOPS
------------------ --------- -------------------------- -------------------------- ------------------ ------ -----
stsw-8020-01 0a - - - - - - -
stsw-8020-01 2b - - - - - - -
stsw-8020-02 0a - - - - - - -
stsw-8020-02 2b - - - - - - -

Power Supply Units:
Crest Power Reset PSU Operational
ID Type Part# Serial# Power Rating Factor Drawn Capable Enabled Firmware Status PSU Location
--- ---- ------------ --------------- -------------- ------ ------- ------- ------- -------- ---------------- ----
1 9C 114-00065+A1 XXT131052637 - - - false true 020F normal rear of the shelf at the bottom left
2 9C 114-00065+A1 XXT131052551 - - - false true 020F normal rear of the shelf at the bottom right

Voltage Sensors:
Voltage Operational
ID (V) Status Sensor Location
--- ------- ---------------------- ------------------------
1 5.70 normal rear of the shelf on the lower left power supply
2 12.300 normal rear of the shelf on the lower left power supply
3 5.70 normal rear of the shelf on the lower right power supply
4 12.180 normal rear of the shelf on the lower right power supply

Current Sensors:
Current Operational
ID (mA) Status Sensor Location
--- ------- ---------------------- ------------------------
1 0 normal rear of the shelf on the lower left power supply
2 0 normal rear of the shelf on the lower left power supply
3 0 normal rear of the shelf on the lower right power supply
4 0 normal rear of the shelf on the lower right power supply

Fans:
Speed Operational
ID (RPM) Status Fan Location
--- ------ ----------------------- ----------------------
1 3000 normal rear of the shelf on the lower left power supply
2 2970 normal rear of the shelf on the lower left power supply
3 3000 normal rear of the shelf on the lower right power supply
4 2970 normal rear of the shelf on the lower right power supply

Temperature:
-- Thresholds °C --
Temp Is Low Low High High Operational
ID °C Ambient Crit Warn Crit Warn Status Sensor Location
--- ---- ------- ---- ---- ---- ---- ------------------ --------------------------------
1 23 true 0 5 42 40 normal front of the shelf on the left, on the OPS panel
2 26 false 5 10 55 50 normal inside of the shelf on the midplane
3 24 false 5 10 55 50 normal rear of the shelf on the lower left power supply
4 39 false 5 10 70 65 normal rear of the shelf on the lower left power supply
5 25 false 5 10 55 50 normal rear of the shelf on the lower right power supply
6 36 false 5 10 70 65 normal rear of the shelf on the lower right power supply
7 25 false 5 10 60 55 normal rear of the shelf at the top left, on shelf module A
8 26 false 5 10 60 55 normal rear of the shelf at the top right, on shelf module B

SAS Ports:
-- Port Speeds Gb/s -- Power Port
Phy # IOM Port Type WWPN Operational Negotiated Status Status
----- --- --------- ----------------- ----------- ---------- ------ -----------
0 A Square 500a098004b063b0 6.0 - - Enabled
1 A Square 500a098004b063b0 6.0 - - Enabled
2 A Square 500a098004b063b0 6.0 - - Enabled
3 A Square 500a098004b063b0 6.0 - - Enabled
4 A Circle 500a09800569f03f 6.0 - - Enabled
5 A Circle 500a09800569f03f 6.0 - - Enabled
6 A Circle 500a09800569f03f 6.0 - - Enabled
7 A Circle 500a09800569f03f 6.0 - - Enabled
8 A Disk 500605ba00c1cb8d 6.0 6.0 on Enabled
9 A Disk 500605ba00c1ea8d 6.0 6.0 on Enabled
10 A Disk 500605ba00c1d111 6.0 6.0 on Enabled
11 A Disk 500605ba00c1bc49 6.0 6.0 on Enabled
12 A Disk 500605ba00c1cdfd 6.0 6.0 on Enabled
13 A Disk 500605ba00c1c531 6.0 6.0 on Enabled
14 A Disk 500605ba00c1eb05 6.0 6.0 on Enabled
15 A Disk 500605ba00c1ec29 6.0 6.0 on Enabled
16 A Disk 500605ba00c1bc29 6.0 6.0 on Enabled
17 A Disk 500605ba00c1c471 6.0 6.0 on Enabled
18 A Disk 500605ba00c039a9 6.0 6.0 on Enabled
19 A Disk 500605ba00c1c4dd 6.0 6.0 on Enabled
20 A Disk - - - - Empty
21 A Disk - - - - Empty
22 A Disk - - - - Empty
23 A Disk - - - - Empty
24 A Disk - - - - Empty
25 A Disk - - - - Empty
26 A Disk - - - - Empty
27 A Disk - - - - Empty
28 A Disk - - - - Empty
29 A Disk - - - - Empty
30 A Disk - - - - Empty
31 A Disk - - - - Empty
32 A SIL - - - - Disabled
33 A SIL - - - - Disabled
34 A SIL - - - - Disabled
35 A SIL - - - - Disabled
0 B Square 500a098004af9e30 6.0 - - Enabled
1 B Square 500a098004af9e30 6.0 - - Enabled
2 B Square 500a098004af9e30 6.0 - - Enabled
3 B Square 500a098004af9e30 6.0 - - Enabled
4 B Circle 500a098005688dbf 6.0 - - Enabled
5 B Circle 500a098005688dbf 6.0 - - Enabled
6 B Circle 500a098005688dbf 6.0 - - Enabled
7 B Circle 500a098005688dbf 6.0 - - Enabled
8 B Disk 500605ba00c1cb8e 6.0 6.0 on Enabled
9 B Disk 500605ba00c1ea8e 6.0 6.0 on Enabled
10 B Disk 500605ba00c1d112 6.0 6.0 on Enabled
11 B Disk 500605ba00c1bc4a 6.0 6.0 on Enabled
12 B Disk 500605ba00c1cdfe 6.0 6.0 on Enabled
13 B Disk 500605ba00c1c532 6.0 6.0 on Enabled
14 B Disk 500605ba00c1eb06 6.0 6.0 on Enabled
15 B Disk 500605ba00c1ec2a 6.0 6.0 on Enabled
16 B Disk 500605ba00c1bc2a 6.0 6.0 on Enabled
17 B Disk 500605ba00c1c472 6.0 6.0 on Enabled
18 B Disk 500605ba00c039aa 6.0 6.0 on Enabled
19 B Disk 500605ba00c1c4de 6.0 6.0 on Enabled
20 B Disk - - - - Empty
21 B Disk - - - - Empty
22 B Disk - - - - Empty
23 B Disk - - - - Empty
24 B Disk - - - - Empty
25 B Disk - - - - Empty
26 B Disk - - - - Empty
27 B Disk - - - - Empty
28 B Disk - - - - Empty
29 B Disk - - - - Empty
30 B Disk - - - - Empty
31 B Disk - - - - Empty
32 B SIL - - - - Disabled
33 B SIL - - - - Disabled
34 B SIL - - - - Disabled
35 B SIL - - - - Disabled

FC Ports:
Port
ID Port Type Status
--- --------- -----------
- - -

Bays:

Has Operational
ID Disk Bay Type Status
--- ----- ----------- -----------
0 true single-disk normal
1 true single-disk normal
2 true single-disk normal
3 true single-disk normal
4 true single-disk normal
5 true single-disk normal
6 true single-disk normal
7 true single-disk normal
8 true single-disk normal
9 true single-disk normal
10 true single-disk normal
11 true single-disk normal
12 false single-disk normal
13 false single-disk normal
14 false single-disk normal
15 false single-disk normal
16 false single-disk normal
17 false single-disk normal
18 false single-disk normal
19 false single-disk normal
20 false single-disk normal
21 false single-disk normal
22 false single-disk normal
23 false single-disk normal


cluster1::>


The following example displays information about the power supplies, voltage sensors and current sensors of the storage shelf 1.1:

    cluster1::> storage shelf show -shelf 1.1 -power

Shelf Name: 1.1
Stack ID: 1
Shelf ID: 1
Shelf UID: 50:0a:09:80:01:cb:d6:84
Serial Number: 6000832415
Module Type: IOM6
Model: DS2246
Shelf Vendor: NETAPP
Disk Count: 12
Connection Type: SAS
Shelf State: Online
Status: Normal

Power Supply Units:
Crest Power Reset PSU Operational
ID Type Part# Serial# Power Rating Factor Drawn Capable Enabled Firmware Status
--- ---- ------------ --------------- -------------- ------ ------- ------- ------- -------- ---------------------
1 9C 114-00065+A1 XXT132835072 - - - false true 020F normal
2 9C 114-00065+A1 XXT132835073 - - - false true 020F normal

Voltage Sensors:
Voltage Operational
ID (V) Status
--- ------- ----------------------
1 5.70 normal
2 12.180 normal
3 5.70 normal
4 12.300 normal

Current Sensors:
Current Operational
ID (mA) Status
--- ------- ----------------------
1 0 normal
2 0 normal
3 3900 normal
4 0 normal

Errors:
------
Critical condition is detected in storage shelf power supply unit "1". The unit might fail.
Critical over temperature failure for temperature sensor "1". Current temperature: "75" C ("167" F).

cluster1::>


The following example displays information about the cooling elements and temperature sensors inside the storage shelf 1.2:

    cluster1::> storage shelf show -shelf 1.2 -cooling

Shelf Name: 1.2
Stack ID: 1
Shelf ID: 2
Shelf UID: 50:0a:09:80:01:b9:75:41
Serial Number: 6000647652
Module Type: IOM6
Model: DS2246
Shelf Vendor: NETAPP
Disk Count: 12
Connection Type: SAS
Shelf State: Online
Status: Normal

Fans:
Speed Operational
ID (RPM) Status
-- ----- -------------
1 3000 normal
2 3000 normal
3 3000 normal
4 2970 normal

Temperature:
-- Thresholds °C --
Temp Is Low Low High High Operational
ID °C Ambient Crit Warn Crit Warn Status
--- ---- ------- ---- ---- ---- ---- ------------------
1 23 true 0 5 42 40 normal
2 26 false 5 10 55 50 normal
3 24 false 5 10 55 50 normal
4 39 false 5 10 70 65 normal
5 25 false 5 10 55 50 normal
6 36 false 5 10 70 65 normal
7 25 false 5 10 60 55 normal
8 27 false 5 10 60 55 normal

Errors:
------
-


cluster1::>


The following example displays information about the connectivity from the node to the storage shelf 1.2:

    cluster1::> storage shelf show -shelf 1.2 -connectivity
Shelf Name: 1.2
Stack ID: 1
Shelf ID: 2
Shelf UID: 50:0a:09:80:01:b9:75:41
Serial Number: 6000647652
Module Type: IOM6
Model: DS2246
Shelf Vendor: NETAPP
Disk Count: 12
Connection Type: SAS
Shelf State: Online
Status: Normal

Paths:

Controller Initiator Initiator Side Switch Port Target Side Switch Port Target Port TPGN
------------------ --------- -------------------------- -------------------------- ------------------ ------
stsw-8020-01 0a - - - -
stsw-8020-01 2b - - - -
stsw-8020-02 0a - - - -
stsw-8020-02 2b - - - -

Errors:
------
-


cluster1::>


The following example displays information about the disk bays of the storage shelf 1.2:

    cluster1::> storage shelf show -shelf 1.2 -bay

Shelf Name: 1.2
Stack ID: 1
Shelf ID: 2
Shelf UID: 50:0a:09:80:01:b9:75:41
Serial Number: 6000647652
Module Type: IOM6
Model: DS2246
Shelf Vendor: NETAPP
Disk Count: 12
Connection Type: SAS
Shelf State: Online
Status: Normal

Bays:

Has Operational
ID Disk Bay Type Status
--- ----- ----------- -----------
0 true single-disk normal
1 true single-disk normal
2 true single-disk normal
3 true single-disk normal
4 true single-disk normal
5 true single-disk normal
6 true single-disk normal
7 true single-disk normal
8 true single-disk normal
9 true single-disk normal
10 true single-disk normal
11 true single-disk normal
12 false single-disk normal
13 false single-disk normal
14 false single-disk normal
15 false single-disk normal
16 false single-disk normal
17 false single-disk normal
18 false single-disk normal
19 false single-disk normal
20 false single-disk normal
21 false single-disk normal
22 false single-disk normal
23 false single-disk normal

Errors:
------
-


cluster1::>


The following example displays information about the ports of the storage shelf 1.2:

    cluster1::> storage shelf show -shelf 1.2 -port

Shelf Name: 1.2
Stack ID: 1
Shelf ID: 2
Shelf UID: 50:0a:09:80:01:b9:75:41
Serial Number: 6000647652
Module Type: IOM6
Model: DS2246
Shelf Vendor: NETAPP
Disk Count: 12
Connection Type: SAS
Shelf State: Online
Status: Normal

SAS Ports:
-- Port Speeds Gb/s -- Power Port
Phy # IOM Port Type WWPN Operational Negotiated Status Status
----- --- --------- ----------------- ----------- ---------- ------ -----------
0 A Square 500a098004b063b0 6.0 - - Enabled
1 A Square 500a098004b063b0 6.0 - - Enabled
2 A Square 500a098004b063b0 6.0 - - Enabled
3 A Square 500a098004b063b0 6.0 - - Enabled
4 A Circle 500a09800569f03f 6.0 - - Enabled
5 A Circle 500a09800569f03f 6.0 - - Enabled
6 A Circle 500a09800569f03f 6.0 - - Enabled
7 A Circle 500a09800569f03f 6.0 - - Enabled
8 A Disk 500605ba00c1cb8d 6.0 6.0 on Enabled
9 A Disk 500605ba00c1ea8d 6.0 6.0 on Enabled
10 A Disk 500605ba00c1d111 6.0 6.0 on Enabled
11 A Disk 500605ba00c1bc49 6.0 6.0 on Enabled
12 A Disk 500605ba00c1cdfd 6.0 6.0 on Enabled
13 A Disk 500605ba00c1c531 6.0 6.0 on Enabled
14 A Disk 500605ba00c1eb05 6.0 6.0 on Enabled
15 A Disk 500605ba00c1ec29 6.0 6.0 on Enabled
16 A Disk 500605ba00c1bc29 6.0 6.0 on Enabled
17 A Disk 500605ba00c1c471 6.0 6.0 on Enabled
18 A Disk 500605ba00c039a9 6.0 6.0 on Enabled
19 A Disk 500605ba00c1c4dd 6.0 6.0 on Enabled
20 A Disk - - - - Empty
21 A Disk - - - - Empty
22 A Disk - - - - Empty
23 A Disk - - - - Empty
24 A Disk - - - - Empty
25 A Disk - - - - Empty
26 A Disk - - - - Empty
27 A Disk - - - - Empty
28 A Disk - - - - Empty
29 A Disk - - - - Empty
30 A Disk - - - - Empty
31 A Disk - - - - Empty
32 A SIL - - - - Disabled
33 A SIL - - - - Disabled
34 A SIL - - - - Disabled
35 A SIL - - - - Disabled
0 B Square 500a098004af9e30 6.0 - - Enabled
1 B Square 500a098004af9e30 6.0 - - Enabled
2 B Square 500a098004af9e30 6.0 - - Enabled
3 B Square 500a098004af9e30 6.0 - - Enabled
4 B Circle 500a098005688dbf 6.0 - - Enabled
5 B Circle 500a098005688dbf 6.0 - - Enabled
6 B Circle 500a098005688dbf 6.0 - - Enabled
7 B Circle 500a098005688dbf 6.0 - - Enabled
8 B Disk 500605ba00c1cb8e 6.0 6.0 on Enabled
9 B Disk 500605ba00c1ea8e 6.0 6.0 on Enabled
10 B Disk 500605ba00c1d112 6.0 6.0 on Enabled
11 B Disk 500605ba00c1bc4a 6.0 6.0 on Enabled
12 B Disk 500605ba00c1cdfe 6.0 6.0 on Enabled
13 B Disk 500605ba00c1c532 6.0 6.0 on Enabled
14 B Disk 500605ba00c1eb06 6.0 6.0 on Enabled
15 B Disk 500605ba00c1ec2a 6.0 6.0 on Enabled
16 B Disk 500605ba00c1bc2a 6.0 6.0 on Enabled
17 B Disk 500605ba00c1c472 6.0 6.0 on Enabled
18 B Disk 500605ba00c039aa 6.0 6.0 on Enabled
19 B Disk 500605ba00c1c4de 6.0 6.0 on Enabled
20 B Disk - - - - Empty
21 B Disk - - - - Empty
22 B Disk - - - - Empty
23 B Disk - - - - Empty
24 B Disk - - - - Empty
25 B Disk - - - - Empty
26 B Disk - - - - Empty
27 B Disk - - - - Empty
28 B Disk - - - - Empty
29 B Disk - - - - Empty
30 B Disk - - - - Empty
31 B Disk - - - - Empty
32 B SIL - - - - Disabled
33 B SIL - - - - Disabled
34 B SIL - - - - Disabled
35 B SIL - - - - Disabled

FC Ports:
Port
ID Port Type Status
--- --------- -----------
- - -

Errors:
------
-


cluster1::>


The following example displays error information about the storage shelves that have errors:

    cluster1::> storage shelf show -errors

Shelf Name: 1.1
Shelf UID: 50:0a:09:80:01:cb:d6:84
Serial Number: 6000832415

Error Type Description
------------------ ---------------------------
Power Critical condition is detected in storage shelf power supply unit "1". The unit might fail.
Temperature Critical over temperature failure for temperature sensor "1". Current temperature: "75" C ("167" F).