storage tape show-errors
Display tape drive errors
Availability: This command is available to cluster administrators at the admin privilege level.
Description
The storage tape show-errors command displays error information about tape drives attached to the cluster. By default, this command displays the following information about all tape drives:
Node to which the tape drive is attached
Device ID of the tape drive
Type of device(tape drive)
Description of the tape drive
Alias name of the tape drive
Tape drive errors
Parameters
- { [-fields <fieldname>, ...]
- If you specify the -fields <fieldname>, ... parameter, the command output also includes the specified field or fields. You can use '-fields ?' to display the fields to specify.
- | [-instance ]}
- If you specify the -instance parameter, the command displays detailed information about all fields.
- [-node {<nodename>|local}] - Node
- Displays detailed information about tape drives on the specified node.
- [-device-id <text>] - Device ID
- Selects the tape drive with the specified device ID.
- [-device-type <text>] - Device Type
- Selects the devices with the specified type of tape drive.
- [-description <text>] - Description
- Selects the tape drives with the specified description.
- [-alias-name <text>] - Alias Name
- Selects the tape drive with the specified alias name.
- [-wwnn <text>] - World Wide Node Name
- Selects the tape drives with the specified World Wide Node Name.
- [-wwpn <text>] - World Wide Port Name
- Selects the tape drive with the specified World Wide Port Name.
- [-serial-number <text>] - Serial Number
- Selects the tape drive with the specified serial number.
- [-error <text>] - Tape Drive Error Description
- Selects the tape drives with the specified error string.
- [-initiator <text>] - Initiator Port
- Selects the tape drives with the specified initiator port.
Examples
The following example shows error information for all tape drives attached to cluster1.
cluster1::> storage tape show-errors
Node: node1
Device ID: 0d.125
Device Type: tape drive
Description: Hewlett-Packard LTO-5
Alias: st0
Errors: hardware error; repair or replace tape drive
Node: node1
Device ID: 2d.0
Device Type: tape drive
Description: IBM LTO-6 ULT3580
Alias: st2
Errors: -
The following example shows error information for tape drive sw4:2.126L1 attached to the node, node1.
cluster1::> storage tape show-errors -device-id sw4:2.126L1 -node node1
Node: node1
Device ID: sw4:2.126L1
Device Type: tape drive
Description: Hewlett-Packard LTO-3
Alias: st3
Errors: -
Give documentation feedback