storage errors show
Display storage configuration errors.
Availability: This command is available to cluster administrators at the admin privilege level.
Description
The storage errors show command displays configuration errors with back end storage arrays.
Parameters
- { [-fields <fieldname>, ...]
- If you specify the -fields <fieldname>, ... parameter, the command output also includes the specified field or fields. You can use '-fields ?' to display the fields to specify.
- | [-instance ]}
- If you specify the -instance parameter, the command displays detailed information about all fields.
- [-uid <text>] - UID
- Selects the disks that match this parameter value.
- [-array-name <array name>] - Array Name
- Selects the disks that have the specified name for the storage array that is connected to the cluster.
- [-node {<nodename>|local}] - Controller Name
- Selects the disks that match this parameter value.
- [-disk <disk path name>] - Disk
- Selects the disks that match this parameter value.
- [-serial-number <text>] - Serial Number
- Selects the disks that match this parameter value.
- [-error-id <integer>, ...] - Error ID
- Selects the disks with error-id values that match this parameter value.
- [-error-type {onepath|onedomain|control|foreign|toobig|toosmall|invalidblocksize|targetasymmap|deviceassymmap|failovermisconfig|unknown|netapp|fwdownrev|qualfail|diskfail|notallflashdisk}, ...] - Error Type
- Selects the disks with error types values that match this parameter value.
Examples
The following example displays configuration errors seen in the system:
cluster1::> storage errors show
Disk: vnv3070f20b:vnci9124s54:1-24.126L23
--------------------
vnci9124s54:1-24.126L23 (600a0b800019e999000036b24bac3983): This array LUN reports an invalid block size and is not usable.
Only a block size of 512 is supported.
Give documentation feedback