Skip to main content

storage shelf acp show

Show connectivity information

Availability: This command is available to cluster administrators at the admin privilege level.

Description

Displays information about the ACP connectivity on each node

Parameters

{ [-fields <fieldname>, ...]
If you specify the -fields <field-name>", ... parameter, the command output also includes the specified field or fields. You can use '-fields ?' to display the fields to specify.
| [-errors ]
If you specify the -errors parameter, the command displays detailed information about all modules with errors.
| [-instance ]}
If you specify the -instance parameter, the command displays detailed information about all fields.
[-node {<nodename>|local}] - Node
Selects the nodes that match this parameter value.
[-is-enabled {true|false}] - Is Enabled?
Selects the nodes that are enabled or disabled.
[-port <text>] - Port
Selects the nodes that match the specified port on which ACP is configured.
[-address <IP Address>] - IP Address
Selects the nodes with the specified IP address.
[-subnet <IP Address>] - Subnet
Selects the nodes with the specified subnet.
[-netmask <IP Address>] - Netmask
Selects the nodes with the specifed netmask.
[-connection-status {no-connectivity|partial-connectivity|full-connectivity|additional-connectivity|unknown-connectivity|not-available|connection-disabled}] - Connection Status
Selects the nodes with the specified connection status.
[-error-id <integer>] - Error ID
Selects the node with the specified error ID.
[-error-type {No-Error|Connection-Issue|Connection-Activity|Module-Error|Shelf-Error}] - Error Type
The error type, in case of a connection error.
[-error-severity {unknown|notice|warning|error|critical}] - Error Severity
The error severity, in case of a connection error.
[-error-text <text>] - Error Text
Selects the node with the specified error text.
[-corrective-action <text>] - Corrective Action
Selects the node with the specified corrective action.
[-channel {unknown|out-of-band|in-band}] - Channel
Selects the nodes that has channel configured out-of-band or in-band.

Examples

The following example displays ACP connectivity on each node (in-band):

fas2750-2n-rtp-1::> storage shelf acp show
Node Channel Connectivity
------------------ -------------------- ----------------------
fas2750-rtp-1a in-band active
fas2750-rtp-1b in-band active
2 entries were displayed.

The following example displays ACP connectivity on each node (out of band):

fas2750-2n-rtp-1::> storage shelf acp show
Node Channel Connectivity
------------------ -------------------- ----------------------
fas2750-rtp-1a out-of-band full-connectivity
fas2750-rtp-1b out-of-band full-connectivity
2 entries were displayed.

The following example displays the -instance output of the storage acp show (in-band) command. Use this command to display details on connectivity and configuration.

fas2750-2n-rtp-1::> storage shelf acp show -instance
Node: fas2750-rtp-1a
Channel: in-band
Enable Status: true
Connection Status: active

Node: fas2750-rtp-1b
Channel: in-band
Enable Status: true
Connection Status: active
2 entries were displayed.

The following example displays the -instance output of the storage acp show (out-of-band) command. Use this command to display details on connectivity and configuration.

fas2750-2n-rtp-1::> storage shelf acp show -instance
Node: fas2750-rtp-1a
Channel: out-of-band
Enable Status: true
Port: e0P
IP Address: 192.168.1.74
Subnet: 192.168.0.1
Netmask: 255.255.252.0
Connection Status: full-connectivity

Node: fas2750-rtp-1b
Channel: out-of-band
Enable Status: true
Port: e0P
IP Address: 192.168.1.75
Subnet: 192.168.0.1
Netmask: 255.255.252.0
Connection Status: full-connectivity
2 entries were displayed.