Skip to main content

system controller memory dimm show

Display the Memory DIMM Table

Availability: This command is available to cluster administrators at the admin privilege level.

Description

The system controller memory dimm show command displays information about the DIMMs in all the nodes in the cluster. These commands are available for 80xx, 25xx and later systems. Earlier models are not supported. By default, the command displays the following information about all the DIMMs in the cluster:

  • Node
  • DIMM name
  • Uncorrectable ECC error count
  • Correctable ECC error count
  • CECC Alert Method
  • CPU socket
  • Channel
  • Slot number
  • Health monitor status
To display more details, use the -instance parameter.

Parameters

{ [-fields <fieldname>, ...]
Selects the fields that you specify.
| [-instance ]}
Displays detailed information about the DIMMs in all the controllers in the cluster.
[-node {<nodename>|local}] - Node
Selects information about the DIMMs in the specified node.
[-pds-id <integer>] - DIMM ID
Selects information about the DIMMs with the specified DIMM ID.
[-slotname <text>] - Slot Name
Selects information about the DIMMs with the specified slot name.
[-socket <integer>] - CPU Socket
Selects information about the DIMMs with the specified socket ID.
[-channel <integer>] - Channel
Selects information about the DIMMs with the specified channel number.
[-slot-no <integer>] - Slot Number on a Channel
Selects information about the DIMMs with the specified slot number.
[-serial <text>] - Serial Number
Selects information about the DIMMs with the specified serial number.
[-part-no <text>] - Part Number
Selects information about the DIMMs with the specified part number.
[-cecc-count <integer>] - Correctable ECC Error Count
Selects information about the DIMMs with the specified correctable ECC error count.
[-uecc-count <integer>] - Uncorrectable ECC Error Count
Selects information about the DIMMs with the specified uncorrectable ECC error count.
[-monitor {node-connect|system-connect|system|controller|chassis|cluster-switch|example}] - Health Monitor Name
Selects information about the DIMMs with the specified health monitor.
[-status {ok|ok-with-suppressed|degraded|unreachable|unknown}] - Status
Selects information about the DIMMs with the specified health monitor status.
[-name <text>] - Unique Name of DIMM
Selects information about the DIMMs with the specified unique name.
[-display-name <text>] - Display Name for the DIMM
Selects information about the DIMMs with the specified display name.
[-alt-cecc-method <text>] - CECC Alert Method
Selects information about the DIMMs with the specified CECC error alert method.
[-alt-cecc-dimm {true|false}] - Replace DIMM
Selects information about the DIMMs with the specified replace DIMM value.

Examples

The example below displays information about the DIMMs in all the nodes in the cluster.

cluster1::> system controller memory dimm show
DIMM UECC CECC Alert CPU Slot
Node Name Count Count Method Socket Channel Number Status
-------------- ------- -------- -------- ------ ------ ------- ------ --------
node1 DIMM-1 0 0 bucket 0 0 0 ok
DIMM-NV1 0 0 bucket 0 1 1 ok
node2 DIMM-1 1 0 bucket 0 0 0 ok
node3 DIMM-NV1 0 0 bucket 0 1 1 ok
4 entries were displayed.

The example below displays detailed information about a specific DIMM in a specific controller.
cluster1::> system controller memory dimm show -instance -node node1 -pds-id 1
Node: node1
DIMM ID: 1
Slot Name: DIMM-1
CPU Socket: 0
Channel: 0
Slot Number on a Channel: 0
Serial Number: AD-01-1306-2EA01E9A
Part Number: HMT82GV7MMR4A-H9
Correctable ECC Error Count: 0
Uncorrectable ECC Error Count: 0
Health Monitor Name: controller
Status: ok
Unique Name of DIMM: DIMM-1
Display Name for the DIMM: DIMM-1
CECC Alert Method: bucket
Replace DIMM: false