storage disk error show
Display disk component and array LUN configuration errors.
Availability: This command is available to cluster administrators at the admin privilege level.
Description
The storage disk error show command displays disk component and array LUN configuration errors.
Parameters
- { [-fields <fieldname>, ...]
- If you specify the -fields <fieldname>, ... parameter, the command output also includes the specified field or fields. You can use '-fields ?' to display the fields to specify.
- | [-instance ]}
- If you specify the -instance parameter, the command displays detailed information about all fields.
- [-uid <text>] - UID
- Displays the error information of the disk whose unique ID matches the value you specify. A disk unique identifier has the form: 20000000:875D4C32:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000
- [-array-name <array name>] - Array Name
- Displays the errors of the storage array whose name you specified.
- [-node {<nodename>|local}] - Controller Name
- Displays the error information for the disks on the clustered node whose name you specified.
- [-disk <disk path name>] - Disk
- Displays detailed error information about the disk you specified.
- [-serial-number <text>] - Serial Number
- Displays the error information for the disk whose serial number you specified.
- [-error-id <integer>, ...] - Error ID
- Displays the error information for the disks whose Error IDs match IDs you specified.
- [-error-type {onepath|onedomain|control|foreign|toobig|toosmall|invalidblocksize|targetasymmap|deviceassymmap|failovermisconfig|unknown|fwdownrev|qualfail|diskfail|notallflashdisk}, ...] - Error Type
- Displays all disk errors of the error types you specified, grouped by type.
- onepath = The array LUN is accessible only via a single path.
- onedomain = The array LUN is accessible only via a single fault domain.
- control = The array LUN cannot be used because it is a control device.
- foreign = The array LUN is marked as foreign and has some external SCSI reservations other than those from Data ONTAP.
- toobig = The array LUN exceeds the maximum array LUN size that Data ONTAP supports.
- toosmall = The array LUN is less than the minimum array LUN size that Data ONTAP supports.
- invalidblocksize = The array LUN is not a valid block size.
- targetasymmap = The array LUN is presented more than once on a single target port.
- deviceassymmap = The array LUN is presented with multiple IDs.
- failovermisconfig = The array LUN is configured with inconsistent failover methods.
- unknown = The array LUN from a storage array that is not supported by this version of Data ONTAP.
- fwdownrev = The disk firmware is a down version.
- qualfail = The disk is not supported.
- diskfail = The disk is in a failed state.
- notallflashdisk = The disk does not match the All-Flash Optimized personality of the system.
Examples
The following example displays configuration errors seen in the system:
cluster1::> storage disk error show
Disk Error Type Error Text
---------------- ----------------- --------------------------------------------
1.02.0 qualfail This disk failed dynamic disk qualification. Update the Disk Qaulification Package.
Give documentation feedback