Skip to main content

system health alert definition show

Display system health alert definition

Availability: This command is available to cluster administrators at the admin privilege level.

Description

The system health alert definition show command displays information about the various alerts defined in the system health monitor policy file. Using -instance will display additional details.

Parameters

{ [-fields <fieldname>, ...]
Selects the fields that you specify.
| [-instance ]}
Use this parameter to display additional information on each alert definition.
  • Node name
  • Monitor name
  • Subsystem identifier
  • Alert ID
  • Severity of the alert
  • Probable cause
  • Probable cause description
  • Possible effect due the error state
  • Recommended corrective actions to be followed
  • Any additional information
  • Additional alert tags
[-node {<nodename>|local}] - Node
Selects the alert definitions for the specified node.
[-monitor <hm_type>] - Monitor
Selects the alert definitions with the specified monitor name.
[-alert-id <text>] - Class of Alert
Selects the alert definitions with the specified alert identifier.
[-perceived-severity <hm_perceived_sev>] - Severity of Alert
Selects the alert definitions with the specified perceived severity.
[-probable-cause <hm_probable_cause>] - Probable Cause
Selects the alert definitions with the specified probable cause of the alert.
[-probable-cause-description <text>] - Probable Cause Description
Selects the alert definitions with the specified probable cause description.
[-possible-effect <text>] - Possible Effect
Selects the alert definitions with the specified possible effect.
[-corrective-actions <text>] - Corrective Actions
Selects the alert definitions with the specified corrective action.
[-subsystem <hm_subsystem>] - Subsystem Name
Selects the alert definitions with the specified subsystem.
[-additional-information <text>] - Additional Relevant Data
Selects the alert definitions with the specified additional information.
[-tags <hm_alert_type>, ...] - Additional Alert Tags
Selects the alert definitions with the specified keywords.

Examples

The example below displays information about all the definitions in the alert definition file:

cluster1::> system health alert definition show 
Node Monitor Subsystem Alert ID
------------- ---------------------- ----------------- -----------------------
node-01 system-connect SAS-connect DualControllerNonHa_
Alert
Severity: Major
Probable Cause: Configuration_error
Probable Cause Description: Disk shelf $(sschm_shelf_info.id) is connected to
two controllers
($(sschm_shelf_info.connected-nodes)) that are
not an HA pair.
Possible Effect: Access to disk shelf $(sschm_shelf_info.id) may
be lost with a single controller failure.
Corrective Actions: 1. Halt all controllers that are connected to disk shelf $(sschm_shelf_info.id).
2. Connect disk shelf $(sschm_shelf_info.id) to both HA controllers following the rules in the Universal SAS and ACP Cabling Guide.
3. Reboot the halted controllers.
4. Contact support personnel if the alert persists.
Additional Info: -
Tags: quality_of_service, nondisruptive-upgrade


The example below displays detailed information about the definitions in the alert definition file:

cluster1::> system health alert definition show -instance

Node: krivC-01
Monitor: system-connect
Class of Alert: DualControllerNonHa_Alert
Severity of Alert: Major
Probable Cause: Configuration_error
Probable Cause Description: Disk shelf $(sschm_shelf_info.id) is connected to two controllers ($(sschm_shelf_info.connected-nodes)) that are not an HA pair.
Possible Effect: Access to disk shelf $(sschm_shelf_info.id) may be lost with a single controller failure.
Corrective Actions: 1. Halt all controllers that are connected to disk shelf $(sschm_shelf_info.id).
2. Connect disk shelf $(sschm_shelf_info.id) to both HA controllers following the rules in the Universal SAS and ACP Cabling Guide.
3. Reboot the halted controllers.
4. Contact support personnel if the alert persists.
Subsystem Name: SAS-connect
Additional Relevant Data: -
Additional Alert Tags: quality_of_service, nondisruptive-upgrade