system service-processor image show
Display the details of currently installed Service Processor firmware image
Availability: This command is available to cluster administrators at the admin privilege level.
Description
The system service-processor image show command displays information about the currently installed firmware images on the Service Processor of each node in a cluster. You can limit output to specific types of information and specific nodes in the cluster, or filter output by specific field values.
Parameters
- { [-fields <fieldname>, ...]
- If you specify the -fields <fieldname>, ... parameter, the command output also includes the specified field or fields. You can use '-fields ?' to display the fields to specify.
- | [-instance ]}
- If you specify the -instance parameter, the command displays detailed information about all fields.
- [-node {<nodename>|local}] - Node
- Selects firmware image information for the Service Processor of the specified node.
- [-image {primary|backup}] - Image
- Selects firmware image information for the Service Processors that are running the primary or backup image as specified.
- [-type {SP|NONE|BMC}] - Type
- Selects firmware image information for the Service Processors of the specified type.
- [-status {installed|corrupt|updating|auto-updating|none}] - Image Status
- Selects firmware image information for the Service Processors whose image status matches the specified value.
- [-is-current {true|false}] - Is Image Current
- Selects firmware image information for the SP whose current image matches the specified status. This parameter indicates the partition (primary or backup) that the SP is currently booted from, not whether the installed firmware version is most current.
- [-version <text>] - Firmware Version
- Selects firmware image information for the Service Processors running the specified firmware version.
- [-autoupdate {true|false}] - Firmware Autoupdate
- Selects firmware image information for the Service Processors whose automatic update matches the specified configuration.
- [-last-update-status {failed|passed}] - Last Update Status
- Selects firmware image information for the Service Processors whose last update is of the specified status.
Examples
The following command displays basic firmware information for the Service Processors of all the nodes.
cluster1::> system service-processor image show
Is
Node Type Image Status Current Version
---------------- ----- ------- ----------- ------- --------
node1 SP
primary installed true 2.2X8
backup installed false 2.2X5
node2 SP
primary installed true 2.2X8
backup installed false 2.2X5
4 entries were displayed.
cluster1::>
cluster1::> system service-processor image show -instance
Node: node1
Image: primary
Type: SP
Image Status: installed
Is Image Current: true
Firmware Version: 2.2X8
Firmware Autoupdate: true
Last Update Status: passed
Node: node1
Image: backup
Type: SP
Image Status: installed
Is Image Current: false
Firmware Version: 2.2X5
Firmware Autoupdate: true
Last Update Status: passed
Node: node2
Image: primary
Type: SP
Image Status: installed
Is Image Current: true
Firmware Version: 2.2X8
Firmware Autoupdate: true
Last Update Status: passed
Node: node2
Image: backup
Type: SP
Image Status: installed
Is Image Current: false
Firmware Version: 2.2X5
Firmware Autoupdate: true
Last Update Status: passed
4 entries were displayed.
cluster1::>
Give documentation feedback