Table 1. Storage specifications
SpecificationDescription

Dimension

  • 4U

  • Height: 175 mm (6.9 inches)

  • Width:
    • With mounting flanges: 483 mm (19.0 inches)

    • Without mounting flanges: 447 mm (17.6 inches)

  • Depth:
    • With cable management arm: 929 mm (36.6 inches)

    • Without cable management arm: 876 mm (34.5 inches)

Weight

49.2 kg (108.5 lb)

Processor

  • Intel 2.2 GHz 10-core processor

  • Two 10-core processors per node

  • 40 total processor core per system

Power supplies

Four hot-swap power supplies for redundancy support

Memory

  • Memory: 128 GB per node, 256 GB in total

  • NVRAM: 16 GB per node, 32 GB in total

  • Type:

    • DDR4-2666, dual-rank, 32 GB ECC RDIMM
    • DDR4-2666, single-rank, 16 GB ECC NVDIMM

Expansion slots

  • Five PCIe slots per node

  • Ten PCIe slots per system

For detailed information, see Rear view.

Input/Output (I/O) features

Rear panel (per node):
  • Four x4 12 Gb MiniSAS HD (SFF-8644) connectors

  • Two 25 GbE SFP28 connectors(for HA interconnect)

  • Two 100 GbE QSFP28 connectors (for cluster interconnect)

  • One RJ-45 1 GbE management ports

  • One RJ-45 console port

  • One Micro-USB console port

  • One USB Type-A connector (Netboot & OS update)

Depending on configuration, the following host ports will be included:
  • Four 16 Gb Fiber Channel SFP+ connectors or;

  • Four 25 GbE SFP28 connectors

Storage controller adapters

  • 2-port 10GBase-T Ethernet, RJ45 port

  • 4-port 10Gb Ethernet, SFP+ port

  • 2-port 25Gb Ethernet, SFP28 port

  • 2-port 100Gb Ethernet, QSFP28 port

  • 4-port 32GB Fiber Channel, SFP+ port

System fans

  • Eight hot-swap system fans

  • System can operate with a single fan failure

Electrical input

The storage system supports up to two hot-swap power supplies for node for redundancy.
Power supply100–120 V ac200–240 V ac
1600-watt 80 PLUS Platinum(50–60 Hz)(50–60 Hz)
YesYes
1600-watt 80 PLUS Titanium(50–60 Hz)(50–60 Hz)
YesYes
Note

Each node can operate with a single failed power supply. The storage system can continue to operate with up to two failed power supplies.

A power supply fan failure will cause power supply to shut down.

Acoustical noise emissions

  • Sound power: 8.5 bels

  • Sound pressure: 67.2 dBA

Environment

The system is supported in the following environment:
  • Air temperature:
    • Operating: ASHRAE class A2: 10–35°C (50–95°F)

    • Shipping or storage: -40–70°C (-40–158°F)

  • Maximum altitude:
    • Operating: 3048 m (10000 ft)

    • Shipping or storage: 12 192 m (40000 ft)

  • Relative humidity (non-condensing):
    • Operating: ASHRAE class A2: 8%–80%; maximum dew point: 21°C (70°F)

    • Shipping or storage: 10%–95%

Your storage complies with ASHARE class A2 specifications. For detailed information, see ASHRAE class compliance information.