Verifying tape device connections
You must ensure that all drives and media changers are visible in Data ONTAP as devices.
- View information about all drives and media changers by using the storage tape show command.
Example
cluster1::> storage tape show
Node: cluster1-01
Device ID Device Type Description Status
---------------------- -------------- ------------------------------ --------
sw4:10.11 tape drive HP LTO-3 normal
0b.125L1 media changer HP MSL G3 Series normal
0d.4 tape drive IBM LTO 5 ULT3580 normal
0d.4L1 media changer IBM 3573-TL normal
... - If a tape drive is not displayed, troubleshoot the problem.
- If a media changer is not displayed, view information about media changers by using the storage tape show-media-changer command, and then troubleshoot the problem.
Example
cluster1::> storage tape show-media-changer
Media Changer: sw4:10.11L1
Description: PX70-TL
WWNN: 2:00a:000e11:10b919
WWPN: 2:00b:000e11:10b919
Serial Number: 00FRU7800000_LL1
Errors: -
Paths:
Node Initiator Alias Device State Status
------------------------ --------- ------- ------------------------ --------
cluster1-01 2b mc0 in-use normal
...
Give documentation feedback