Skip to main content

816f000d-0407ffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName]. (Comput HDD6 Pres)

The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName]. (Comput HDD6 Pres)

This message is for the use case when an implementation has detected a Drive has been Removed.

May also be shown as 816f000d0407ffff or 0x816f000d0407ffff

Severity

Error

Alert Category

Critical - Hard Disk drive

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0163

SNMP Trap ID

5

Automatically Notify Support

No

User Response

  1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling the drive.
  2. Make sure that the disk firmware and RAID controller and backplane firmware are at the latest level.
  3. Check the SAS cable.
  4. Replace the hard disk drive.