FQXSFMA0053G : An uncorrected memory error has been recovered by mirror on DIMM [arg1] at address [arg2].[arg3]
An uncorrected memory error has been recovered by mirror on DIMM [arg1] at address [arg2].[arg3]
Parameters
[arg1] DIMM Silk Label, 1-based
[arg2] Address of the system where the error occurred
[arg3] DIMM identifier consists of S/N, FRU and UDI, e.g. "739E68ED-VC10 FRU 0123456"
This message is reported when an uncorrected memory error has been recovered by mirror.
Severity
Warning
User Action
Complete the following steps:
- Keep the system running until next planned maintenance window.
- During planned maintenance, power off the system and remove A/C power.
- Reseat the failing DIMM identified by LightPath and/or event log entry.
- Restore A/C power and power on the system.
- Check Lenovo Support site for an applicable service bulletin or firmware update that applies to this memory error.
- If the problem persists, collect service data logs and contact Lenovo Support.
Enviar feedback