10 x U.3 AnyBay backplane (two processors)
Use this section to understand the cable routing for ten U.3 AnyBay drives with two processors installed.
Cable routing for 10 x U.3 AnyBay drives and 1 x 16i SFF RAID adapter (Gen 4)
Figure 1. Cable routing for 10 x U.3 AnyBay drives and 1 x 16i SFF RAID adapter (Gen 4)


From | To | Cable length |
---|---|---|
1 SAS 0 and SAS 1 connector on backplane | 1 C0 connector on RAID adapter | 900/1020 mm |
2 Power connector on backplane | 2 Power connector 2A connector on processor board | 480 mm |
3 SAS 2 connector on backplane | 3 C1 connector on RAID adapter | 900 mm |
Cable routing for 10 x U.3 AnyBay drives and 1 x 16i CFF RAID adapter (Gen 4)
Figure 2. Cable routing for 10 x U.3 AnyBay drives and 1 x 16i CFF RAID adapter (Gen 4)


From | To | Cable length |
---|---|---|
1 SAS 0 connector on backplane | 1 C0 connector on RAID adapter | 175 mm |
2 Power connector on backplane | 2 Power connector 2A on processor board | 480 mm |
3 SAS 1 connector on backplane | 3 C1 connector on RAID adapter | 150 mm |
4 SAS 2 connector on backplane | 4 C2 connector on RAID adapter | 210 mm |
5 Power connector on RAID adapter | 5 Internal RAID power connector on processor board | 210 mm |
6 Input connector on RAID adapter | 6 PCIe connector 2 on processor board | 450 mm |
Cable routing for 10 x U.3 AnyBay drives, rear 2 x U.3 AnyBay drives, and 1 x 16i SFF RAID adapter (Gen 4)
Figure 3. Cable routing for 10 x U.3 AnyBay drives, rear 2 x U.3 AnyBay drives, and 1 x 16i SFF RAID adapter (Gen 4)


From | To | Cable length |
---|---|---|
1 SAS 0 and SAS 1 connectors on front backplane | 1 C0 connector on RAID adapter | 900/1020 mm |
2 Power connector on front backplane | 2 Power connector 2A on processor board | 480 mm |
3 SAS 2 connector on front backplane and SAS connector on rear backplane | 3 C1 connector on RAID adapter | 270/760 mm |
4 Power connector on rear backplane | 4 Power connector 15 on processor board | 250 mm |
Cable routing for 10 x U.3 AnyBay drives, rear 2 x U.3 AnyBay drives, and 1 x 16i CFF RAID adapter (Gen 4)
Figure 4. Cable routing for 10 x U.3 AnyBay drives, rear 10 x U.3 AnyBay drives, and 1 x 16i CFF RAID adapter (Gen 4)


From | To | Cable length |
---|---|---|
1 SAS 0 connector on front backplane | 1 C0 connector on RAID adapter | 175 mm |
2 Input connector on RAID adapter | 2 PCIe connector 2 on processor board | 450 mm |
3 Power connector on front backplane | 3 Power connector 2A on processor board | 480 mm |
4 SAS 1 connector on front backplane | 4 C1 connector on RAID adapter | 150 mm |
5 SAS 2 connector on front backplane | 5 C2 connector on RAID adapter | 210 mm |
6 Power connector on RAID adapter | 6 Internal RAID power connector on processor board | 210 mm |
7 SAS connector on rear backplane | 7 C3 connector on RAID adapter | 810 mm |
8 Power connector on rear backplane | 8 Power connector 15 on processor board | 250 mm |
Enviar feedback