FQXSPCA0035M : Non-redundant:Insufficient Resources for [RedundancySetElementName] has asserted.

Non-redundant:Insufficient Resources for [RedundancySetElementName] has asserted.

This message is for the use case when a Redundancy Set has transitioned to Non-redundant:Insufficient Resources.

Severity

Error

Alert Category

Critical - Fan Failure

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0810

SNMP Trap ID

11

Automatically Notify Support

No

User Action

Complete the following steps until the problem is solved:

  1. Make sure that the connectors on fan n are not damaged.
  2. Make sure that the fan n connectors on the system board are not damaged.
  3. Make sure that the fans are correctly installed.
  4. Reseat the fans.
  5. Replace the fans. (n = fan number)