Skip to main content

FQXSPPW0104J : Non-redundant:Sufficient Resources from Redundancy Degraded or Fully Redundant for [RedundancySetElementName] has asserted.

Non-redundant:Sufficient Resources from Redundancy Degraded or Fully Redundant for [RedundancySetElementName] has asserted.

This message is for the use case when a Redundancy Set has transitioned from Redundancy Degraded or Fully Redundant to Non-redundant:Sufficient.

Severity

Warning

Alert Category

Warning - Redundant Power Supply

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0806

SNMP Trap ID

10

Automatically Notify Support

No

User Action

Check power supply LEDs:

  1. If AC LED is not lit, check power cord and input voltage.
  2. If DC LED is not lit, remove and reinstall power supply.
  3. If error LED is lit, replace the power supply.