Adding capacity disks
You can increase the size of an existing non-root aggregate or a root aggregate containing disks by adding capacity disks. You can use Storage Manager to add HDDs or SSDs of the selected ONTAP disk type and to modify the RAID group options.
Before you begin
The aggregate must be online.
There must be sufficient compatible spare disks.
About this task
It is a best practice to add disks that are of the same size as the other disks in the aggregate.
If you add disks that are smaller in size than the other disks in the aggregate, the aggregate becomes suboptimal in configuration, which in turn might cause performance issues.
If you add disks that are larger in size than the disks that are available in a pre-existing RAID group within the aggregate, then the disks are downsized, and their space is reduced to that of the other disks in that RAID group. If a new RAID group is created in the aggregate and similar sized disks remain in the new RAID group, the disks are not downsized.
If you add disks that are not of the same size as the other disks in the aggregate, the selected disks might not be added; instead, other disks with a usable size between 90 percent and 105 percent of the specified size are automatically added. For example, for a 744 GB disk, all of the disks in the range of 669 GB through 781 GB are eligible for selection. For all of the spare disks in this range, ONTAP first selects only partitioned disks, then selects only unpartitioned disks, and finally selects both partitioned disks and unpartitioned disks.
You cannot use Storage Manager to add HDDs to the following configurations:
Aggregates containing only SSDs
Root aggregates containing partitioned disks
You must use the command-line interface to add HDDs to these configurations.
Shared disks support two RAID types: RAID DP and RAID-TEC.
You cannot use SSDs with storage pool.
If the RAID group type is RAID DP, and if you are adding FSAS or MSATA type of disks that are equal to or larger than 10 TB in size, then you can add them only to Specific RAID group , and not to New RAID group or All RAID groups .
The disks are added after downsizing the disk size to the size of the disks in the pre-existing RAID group of the existing aggregate.
If the RAID group type is RAID-TEC, and if you are adding FSAS or MSATA type of disks that are equal to or larger than 10 TB in size, then you can add them to All RAID groups , New RAID group , and Specific RAID group .
The disks are added after downsizing the disk size to the size of the disks in the pre-existing RAID group of the existing aggregate.
Result
The capacity disks are added to the selected aggregate, and the aggregate size is increased.