Changes in the CLI and script commands in this release
This topic lists changes in the latest ThinkSystem System Manager releases of the CLI command and Script commands.
ThinkSystem SAN OS 11.60.2
The Command Line Interface for release 11.60.2 can only be performed over the secure Ethernet management interface. In-band management over the host connections is not supported. The following tables list changes to the CLI and Script Commands for release 11.60.2.
Command | Description of Change |
---|---|
Set controller host port properties | Added Physical and Virtual values for host Port parameter. |
Save storage array support data | Added object-bundle.json data type. |
Save auto-load balancing statistics | Added "Drive Lost Primary Path" note |
Download environmental card firmware | Updated Important note. |
Set thin volume attributes | Update repositoryMaxCapacity and addRepositoryCapacity parameters. |
Set storage array to enable or disable automatic load balancing | Added "Drive Lost Primary Path" note |
Create initiator | Added NVMe over RoCE and NVMe over Fibre Channel compatibility. |
Delete initiator | Added NVMe over RoCE and NVMe over Fibre Channel compatibility. |
Set initiator | Added NVMe over RoCE and NVMe over Fibre Channel compatibility. |
Create snapshot group | Added a note to the context section. |
Set controller host port properties | Modifed the description of the maxFramePayload portSpeed parameters. Added information about the NVMe over RoCE settings. Noted that the IPv4VlanId, IPv6VlanId, IPv4Priority, IPv6Priority, enableIPv6Priority, enableIPv4Priority, enableIPv6Vlan, and enableIPv4Vlan parameters are not supported in an NVMe over RoCE environment. |
ThinkSystem SAN OS 11.50.3
The in-band CLI for release 11.50.3 supports in-band management for controllers running all firmware releases including 11.60.2.
ThinkSystem SAN OS 11.50.2 and below
This release contains only minor enhancements and fixes.