Obtain the feature pack
To obtain the feature pack, you need the serial number from the controller shelf, a Feature Code, and the Feature Enable Identifier for the storage array.
- Locate the serial number.
- From ThinkSystem System Manager, select Support > Support Center.
- With the Support Resources tab selected, scroll to the View top storage array properties section.
- Locate the Chassis Serial Number, and copy this value to a text file.
- Locate the feature pack submodel ID.
- From the ThinkSystem System Manager, select Support.
- Select the Support Center tile.
- On the Support Resources tab, locate and select the Storage Array Profile link.
- Type feature pack submodel ID in the text box, and click Find.
- Locate the feature pack submodel ID for the starting configuration.
- Using the feature pack submodel ID, locate the corresponding Controller submodel ID for the starting configuration and find the Feature Code for the desired ending configuration within the table below. Then, copy that Feature Code to a text file.NoteBaseboard ports are disabled when running an NVMe protocol on the HIC.
Starting configuration Ending configuration Feature Code Controller Submodel ID Baseboard Ports Controller Submodel ID Baseboard Ports DE2000H 422 FC
423 iSCSI
B4DH 423 iSCSI
422 FC
B4XC Starting configuration Ending configuration Feature Code Controller Submodel ID Baseboard Ports HIC Ports* Controller Submodel ID Baseboard Ports HIC Ports* DE4000H 424 FC
FC
425 iSCSI
FC
B4XH 424 FC
FC
427 iSCSI
iSCSI
B4E1 424 FC
FC
426 FC
iSCSI
B4XK 425 iSCSI
FC
424 FC
FC
B4XJ 425 iSCSI
FC
426 FC
iSCSI
B4XM 425 iSCSI
FC
427 iSCSI
iSCSI
B4XP 426 FC
iSCSI
424 FC
FC
B4XL 426 FC
iSCSI
425 iSCSI
FC
B4XN 426 FC
iSCSI
427 iSCSI
iSCSI
B4XR 427 iSCSI
iSCSI
424 FC
FC
B4XG 427 iSCSI
iSCSI
425 iSCSI
FC
B4XQ 427 iSCSI
iSCSI
426 FC
iSCSI
B4XS DE4000F 428 FC
FC
429 iSCSI
FC
B4DK 428 FC
FC
430 FC
iSCSI
B4XU 428 FC
FC
431 iSCSI
iSCSI
B4G7 429 iSCSI
FC
428 FC
FC
B4DL 429 iSCSI
FC
430 FC
iSCSI
B4XW 429 iSCSI
FC
431 iSCSI
iSCSI
B4XY 430 FC
iSCSI
428 FC
FC
B4XV 430 FC
iSCSI
429 iSCSI
FC
B4XX 430 FC
iSCSI
431 iSCSI
iSCSI
B4Y0 431 iSCSI
iSCSI
428 FC
FC
B4XT 431 iSCSI
iSCSI
429 iSCSI
FC
B4XZ 431 iSCSI
iSCSI
430 FC
iSCSI
B4LZ NoteHIC port protocol settings only apply to the configurable Lenovo ThinkSystem DE4000 HIC, 16Gb FC/10GbE, 4 ports, Option p/n 4C57A14366.Starting configuration Ending configuration Feature Code Controller Submodel ID Baseboard Ports HIC Ports Controller Submodel ID Baseboard Ports HIC Ports DE6000H 432 FC
Per HIC
433 iSCSI
Per HIC
B4JM 433 iSCSI
Per HIC
432 FC
Per HIC
B4XD 441 Disabled
NVMe-oF
433 iSCSI
Per HIC
B6Z0 433 iSCSI
Per HIC
441 Disabled
NVMe-oF
B6Z1 441 Disabled
NVMe-oF
432 FC
Per HIC
B6Z2 432 FC
Per HIC
441 Disabled
NVMe-oF
B6Z3 DE6000F 434 FC
Per HIC
435 iSCSI
Per HIC
B4JK 435 iSCSI
Per HIC
434 FC
Per HIC
B4XE 442 Disabled
NVMe-oF
435 iSCSI
Per HIC
B6Z4 435 iSCSI
Per HIC
442 Disabled
NVMe-oF
B6Z5 442 Disabled
NVMe-oF
434 FC
Per HIC
B6Z6 434 FC
Per HIC
442 Disabled
NVMe-oF
B6Z7 NoteNVMe-oF includes NVMe over RoCE and NVMe over Fibre Channel, based on the installed HIC.
If your Controller submodel ID is not listed, contact DE Series Product Support Site.
- In System Manager, locate the Feature Enable Identifier.
- Go to Settings > System.
- Scroll down to Add-ons.
- Under Change Feature Pack, locate the Feature Enable Identifier.
- Copy and paste this 32-digit number to a text file.
- Go to Lenovo Features on Demand, click on Storage Host Protocol Change, and enter the information required to obtain the feature pack.
Feature Code
Machine Type
Chassis serial number
Feature Enable Identifier (UID)
- Choose whether to receive the key file for the feature pack in an email or download it directly from the site.
Go to Stop host I/O.