Skip to main content

Obtain the feature pack

To obtain the feature pack, you need the serial number from the controller shelf, a Feature Code, and the Feature Enable Identifier for the storage array.

  1. Locate the serial number.
    1. From ThinkSystem System Manager, select Support > Support Center.
    2. With the Support Resources tab selected, scroll to the View top storage array properties section.
    3. Locate the Chassis Serial Number, and copy this value to a text file.


  2. Locate the feature pack submodel ID.
    1. From the ThinkSystem System Manager, select Support.
    2. Select the Support Center tile.
    3. On the Support Resources tab, locate and select the Storage Array Profile link.
    4. Type feature pack submodel ID in the text box, and click Find.
    5. Locate the feature pack submodel ID for the starting configuration.


  3. Using the feature pack submodel ID, locate the corresponding Controller submodel ID for the starting configuration and find the Feature Code for the desired ending configuration within the table below. Then, copy that Feature Code to a text file.
    Note
    Baseboard ports are disabled when running an NVMe protocol on the HIC.
    Starting configurationEnding configurationFeature Code
    Controller Submodel IDBaseboard PortsController Submodel IDBaseboard Ports
    DE2000H
    422

    FC

    423

    iSCSI

    B4DH
    423

    iSCSI

    422

    FC

    B4XC
    Starting configurationEnding configurationFeature Code
    Controller Submodel IDBaseboard PortsHIC Ports*Controller Submodel IDBaseboard PortsHIC Ports*
    DE4000H
    424

    FC

    FC

    425

    iSCSI

    FC

    B4XH
    424

    FC

    FC

    427

    iSCSI

    iSCSI

    B4E1
    424

    FC

    FC

    426

    FC

    iSCSI

    B4XK
    425

    iSCSI

    FC

    424

    FC

    FC

    B4XJ
    425

    iSCSI

    FC

    426

    FC

    iSCSI

    B4XM
    425

    iSCSI

    FC

    427

    iSCSI

    iSCSI

    B4XP
    426

    FC

    iSCSI

    424

    FC

    FC

    B4XL
    426

    FC

    iSCSI

    425

    iSCSI

    FC

    B4XN
    426

    FC

    iSCSI

    427

    iSCSI

    iSCSI

    B4XR
    427

    iSCSI

    iSCSI

    424

    FC

    FC

    B4XG
    427

    iSCSI

    iSCSI

    425

    iSCSI

    FC

    B4XQ
    427

    iSCSI

    iSCSI

    426

    FC

    iSCSI

    B4XS
    DE4000F
    428

    FC

    FC

    429

    iSCSI

    FC

    B4DK
    428

    FC

    FC

    430

    FC

    iSCSI

    B4XU
    428

    FC

    FC

    431

    iSCSI

    iSCSI

    B4G7
    429

    iSCSI

    FC

    428

    FC

    FC

    B4DL
    429

    iSCSI

    FC

    430

    FC

    iSCSI

    B4XW
    429

    iSCSI

    FC

    431

    iSCSI

    iSCSI

    B4XY
    430

    FC

    iSCSI

    428

    FC

    FC

    B4XV
    430

    FC

    iSCSI

    429

    iSCSI

    FC

    B4XX
    430

    FC

    iSCSI

    431

    iSCSI

    iSCSI

    B4Y0
    431

    iSCSI

    iSCSI

    428

    FC

    FC

    B4XT
    431

    iSCSI

    iSCSI

    429

    iSCSI

    FC

    B4XZ
    431

    iSCSI

    iSCSI

    430

    FC

    iSCSI

    B4LZ
    Note
    HIC port protocol settings only apply to the configurable Lenovo ThinkSystem DE4000 HIC, 16Gb FC/10GbE, 4 ports, Option p/n 4C57A14366.
    Starting configurationEnding configurationFeature Code
    Controller Submodel IDBaseboard PortsHIC PortsController Submodel IDBaseboard PortsHIC Ports
    DE6000H
    432

    FC

    Per HIC

    433

    iSCSI

    Per HIC

    B4JM
    433

    iSCSI

    Per HIC

    432

    FC

    Per HIC

    B4XD
    441

    Disabled

    NVMe-oF

    433

    iSCSI

    Per HIC

    B6Z0
    433

    iSCSI

    Per HIC

    441

    Disabled

    NVMe-oF

    B6Z1
    441

    Disabled

    NVMe-oF

    432

    FC

    Per HIC

    B6Z2
    432

    FC

    Per HIC

    441

    Disabled

    NVMe-oF

    B6Z3
    DE6000F
    434

    FC

    Per HIC

    435

    iSCSI

    Per HIC

    B4JK
    435

    iSCSI

    Per HIC

    434

    FC

    Per HIC

    B4XE
    442

    Disabled

    NVMe-oF

    435

    iSCSI

    Per HIC

    B6Z4
    435

    iSCSI

    Per HIC

    442

    Disabled

    NVMe-oF

    B6Z5
    442

    Disabled

    NVMe-oF

    434

    FC

    Per HIC

    B6Z6
    434

    FC

    Per HIC

    442

    Disabled

    NVMe-oF

    B6Z7
    Note
    • NVMe-oF includes NVMe over RoCE and NVMe over Fibre Channel, based on the installed HIC.

    • If your Controller submodel ID is not listed, contact DE Series Product Support Site.

  4. In System Manager, locate the Feature Enable Identifier.
    1. Go to Settings > System.
    2. Scroll down to Add-ons.
    3. Under Change Feature Pack, locate the Feature Enable Identifier.
    4. Copy and paste this 32-digit number to a text file.


  5. Go to Lenovo Features on Demand, click on Storage Host Protocol Change, and enter the information required to obtain the feature pack.
    • Feature Code

    • Machine Type

    • Chassis serial number

    • Feature Enable Identifier (UID)

  6. Choose whether to receive the key file for the feature pack in an email or download it directly from the site.