Add trap destinations for SNMP alerts
You can add up to 10 servers for sending SNMP traps.
Before you begin
The network server you want to add must be configured with an SNMP service application. You need the network address of this server (either an IPv4 or an IPv6 address), so the event monitor can send trap messages to that address. You can use more than one server (up to 10 servers are allowed).
A community name must be created, consisting of only printable ASCII characters. The community name, which is a string that acts like a password for the network servers, is typically created by a network administrator. Up to 256 communities can be created.
The management information base (MIB) file has been copied and compiled on the server with the SNMP service application. This MIB file defines the data being monitored and managed.
If you do not have the MIB file, you can obtain it from the Lenovo Data Center Support site:
Click Downloads.
Click Software.
Find your management software (for example, ThinkSystem System Manager ), and then click Go! on the right.
Click View & Download on the latest version.
Click Continue at the bottom of the page.
Accept the EULA.
Scroll down until you see MIB file for SNMP traps, and then click the link to download the file.
What happens next?
The event monitor sends SNMP traps to the server(s) whenever an alertable event occurs.