Configuring SRA using array manager
You can configure Storage Replication Adapter (SRA) by using the Array Manager wizard of Site Recovery Manager (SRM) to enable interactions between SRM and storage virtual machines (SVMs).
- You must have paired the protected sites and recovery sites in SRM.
You must have configured your storage before configuring the array manager.
- You must have configured and replicated the SnapMirror relationships between the protected sites and recovery sites.
- You must have enabled the SVM management LIFs to enable multitenancy.
SRA supports cluster-level management and SVM-level management. If you add storage at a cluster level, then you can discover and perform operations on all of the SVMs in the cluster. If you add storage at an SVM level, then you can manage only that specific SVM.
Note
VMware does not support NFS4.1 protocol for SRM.
- In SRM, click Array Managers, and then click Add Array Manager.
- Enter the following information to describe the array in SRM:
- Click Next.
- Verify that the array is discovered and displayed at the bottom of the Add Array Manager window.
- Click Finish.
You can follow the same steps for the recovery site by using the appropriate SVM management IP addresses and credentials. On the Enable Array Pairs screen of the Add Array Manager wizard, you should verify that the correct array pair is selected, and that it shows as ready to be enabled.