The following messages can result when you run the DSA Intel network test.

  • 406-000-000 : IANet:Registers Test Passed

    The test passed.
    Recoverable
    No
    Severity
    Event
    Serviceable
    No
    Automatically notify support
    No
    Related links
  • 406-001-000 : IANet:EEPROM Test Passed

    The test passed.
    Recoverable
    No
    Severity
    Event
    Serviceable
    No
    Automatically notify support
    No
    Related links
  • 406-002-000 : IANet:FIFO Test Passed

    The test passed.
    Recoverable
    No
    Severity
    Event
    Serviceable
    No
    Automatically notify support
    No
    Related links
  • 406-003-000 : IANet:Interrupts Test Passed

    The test passed.
    Recoverable
    No
    Severity
    Event
    Serviceable
    No
    Automatically notify support
    No
    Related links
  • 406-004-000 : IANet:Loopback Test Passed

    The test passed.
    Recoverable
    No
    Severity
    Event
    Serviceable
    No
    Automatically notify support
    No
    Related links
  • 406-800-000 : IANet:Registers Test Aborted

    Registers test was canceled.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    No
    Automatically notify support
    No
    Related links
  • 406-801-000 : IANet:EEPROM Test Aborted

    EEPROM test was canceled.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    No
    Automatically notify support
    No
    Related links
  • 406-802-000 : IANet:FIFO Test Aborted

    FIFO test was canceled.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    No
    Automatically notify support
    No
    Related links
  • 406-803-000 : IANet:Interrupts Test Aborted

    Interrupt test was canceled.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    No
    Automatically notify support
    No
    Related links
  • 406-804-000 : IANet:Loopback Test Aborted

    Loopback test was canceled.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    No
    Automatically notify support
    No
    Related links
  • 406-900-000 : IANet:Registers Test Failed

    A failure was detected during the Registers test.
    Recoverable
    No
    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Complete the following steps:
    1. Check component firmware level and upgrade if necessary. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
    2. Rerun the test.
    3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
    Related links
  • 406-901-000 : IANet:EEPROM Test Failed

    A failure was detected during the EEPROM test.
    Recoverable
    No
    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Complete the following steps:
    1. Check component firmware level and upgrade if necessary. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
    2. Rerun the test.
    3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
    Related links
  • 406-902-000 : IANet:FIFO Test Failed

    A failure was detected during the FIFO test.
    Recoverable
    No
    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Complete the following steps:
    1. Check component firmware level and upgrade if necessary. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
    2. Rerun the test.
    3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
    Related links
  • 406-903-000 : IANet:Interrupts Test Failed

    A failure was detected during the Interrupt test.
    Recoverable
    No
    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Complete the following steps:
    1. Check component firmware level and upgrade if necessary. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
    2. Rerun the test.
    3. Check interrupt assignments in the PCI Hardware section of the DSA Diagnostic Log. If the ethernet device is sharing interrupts, if possible modify the interrupt assignments using F1 Setup to assign a unique interrupt to the device.
    4. Rerun the test.
    5. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
    Related links
  • 406-904-000 : IANet:Loopback Test Failed

    A failure was detected during the Loopback test.
    Recoverable
    No
    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Complete the following steps:
    1. Check the Ethernet cable for damage and ensure correct cable type and attachment.
    2. Check component firmware level and upgrade if necessary. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
    3. Rerun the test.
    4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
    Related links