Test results for the DSA system management test
The following messages can result when you run the DSA system management test.
166-000-001 : IMM I2C Test Passed
IMM I2C Test Passed.- Recoverable
- No
- Severity
- Event
- Serviceable
- No
- Automatically notify support
- No
- Related links
166-801-001 : IMM I2C Test Aborted
IMM returned incorrect response length.- Recoverable
- No
- Severity
- Warning
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Related links
166-802-001 : IMM I2C Test Aborted
Test cannot be completed for unknown reason.- Recoverable
- No
- Severity
- Warning
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Related links
166-803-001 : IMM I2C Test Aborted
Node Busy. Try later.- Recoverable
- No
- Severity
- Warning
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Related links
166-804-001 : IMM I2C Test Aborted
Invalid Command.- Recoverable
- No
- Severity
- Warning
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Related links
166-805-001 : IMM I2C Test Aborted
Invalid Command for given LUN.- Recoverable
- No
- Severity
- Warning
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Related links
166-806-001 : IMM I2C Test Aborted
Timeout while processing command.- Recoverable
- No
- Severity
- Warning
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Related links
166-807-001 : IMM I2C Test Aborted
Out of space.- Recoverable
- No
- Severity
- Warning
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Related links
166-808-001 : IMM I2C Test Aborted
Reservation Canceled or Invalid Reservation ID.- Recoverable
- No
- Severity
- Warning
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Related links
166-809-001 : IMM I2C Test Aborted
Request data truncated.- Recoverable
- No
- Severity
- Warning
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Related links
166-810-001 : IMM I2C Test Aborted
Request data length invalid.- Recoverable
- No
- Severity
- Warning
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Related links
166-811-001 : IMM I2C Test Aborted
Request data field length limit exceeded.- Recoverable
- No
- Severity
- Warning
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Related links
166-812-001 : IMM I2C Test Aborted
Parameter out of range.- Recoverable
- No
- Severity
- Warning
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Related links
166-813-001 : IMM I2C Test Aborted
Cannot return number of requested data bytes.- Recoverable
- No
- Severity
- Warning
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Related links
166-814-001 : IMM I2C Test Aborted
Requested Sensor, data, or record not present.- Recoverable
- No
- Severity
- Warning
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Related links
166-815-001 : IMM I2C Test Aborted
Invalid data field in Request.- Recoverable
- No
- Severity
- Warning
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Related links
166-816-001 : IMM I2C Test Aborted
Command illegal for specified sensor or record type.- Recoverable
- No
- Severity
- Warning
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Related links
166-817-001 : IMM I2C Test Aborted
Command response could not be provided.- Recoverable
- No
- Severity
- Warning
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Related links
166-818-001 : IMM I2C Test Aborted
Cannot execute duplicated request.- Recoverable
- No
- Severity
- Warning
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Related links
166-819-001 : IMM I2C Test Aborted
Command response could not be provided. SDR Repository in?update mode.- Recoverable
- No
- Severity
- Warning
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Related links
166-820-001 : IMM I2C Test Aborted
Command response could not be provided. Device in firmware update mode.- Recoverable
- No
- Severity
- Warning
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Related links
166-821-001 : IMM I2C Test Aborted
Command response could not be provided. BMC initialization in progress.- Recoverable
- No
- Severity
- Warning
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Related links
166-822-001 : IMM I2C Test Aborted
Destination unavailable.- Recoverable
- No
- Severity
- Warning
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Related links
166-823-001 : IMM I2C Test Aborted
Cannot execute command. Insufficient privilege level.- Recoverable
- No
- Severity
- Warning
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Related links
166-824-001 : IMM I2C Test Aborted
Cannot execute command.- Recoverable
- No
- Severity
- Warning
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Related links
166-901-001 : IMM I2C Test Failed
IMM Indicates failure in RTMM bus (BUS 0).- Recoverable
- No
- Severity
- Error
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Run the test again.
- If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
- Related links
166-902-001 : IMM I2C Test Failed
IMM Indicates failure in TPM bus (BUS 1).- Recoverable
- No
- Severity
- Error
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Run the test again.
- If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
- Related links
166-903-001 : IMM I2C Test Failed
IMM Indicates failure in FPGA bus (BUS 2).- Recoverable
- No
- Severity
- Error
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Run the test again.
- If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
- Related links
166-904-001 : IMM I2C Test Failed
IMM Indicates failure in Lightpath bus (BUS 3).- Recoverable
- No
- Severity
- Error
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Run the test again.
- If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
- Related links
166-905-001 : IMM I2C Test Failed
IMM Indicates failure in SAS/SEP/BP bus (BUS 4).- Recoverable
- No
- Severity
- Error
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Run the test again.
- If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
- Related links
166-906-001 : IMM I2C Test Failed
IMM Indicates failure in Patsburg bus (BUS 5).- Recoverable
- No
- Severity
- Error
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Run the test again.
- If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
- Related links
166-907-001 : IMM I2C Test Failed
IMM Indicates failure in Mezz card bus (BUS 6).- Recoverable
- No
- Severity
- Error
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Perform the actions mentioned one at a time and try the test after each action:
- Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
- Make sure that DSA and BMC/IMM are at the latest level.
- Run the test again.
- If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
- Related links