Skip to main content

Locally: LAN over USB

If you omit any optional parameter, the default value is used. If one or more default values are used and the ASU cannot access the IMM2 by using the LAN over USB access method, the ASU automatically uses the KCS access method.

To update the UUID, in the ASU command-line interface, enter the following command:

asu set SYSTEM_PROD_DATA.SysInfoUUID uuid     [--user userid][--password password]

where:

uuid
is the user-assigned hexadecimal value, up to 16 bytes, that identifies the compute node.
userid
is the IMM2 account name (1 of 12 accounts). The default is USERID.
password
is the IMM2 account password (1 of 12 accounts). The default is PASSW0RD (with a zero, not the letter O).

To update the DMI/SMBIOS data, complete the following steps:

  1. In the ASU command-line interface, enter the following command:
    asu set SYSTEM_PROD_DATA.SysInfoProdName <em className="ph i">xxxxyyy</em>
    [--user <em className="ph i">userid</em>][--password <em className="ph i">password</em>]
    Important
    The default machine type and model number in the system-board firmware might not be the machine type and model number of the compute node. Make sure that you enter the correct machine type and model number.

    where:

    xxxx
    is the 4-digit machine type of the compute node.
    yyy
    is the 3-digit model number of the compute node.
    userid
    is the IMM2 account name (1 of 12 accounts). The default is USERID.
    password
    is the IMM2 account password (1 of 12 accounts). The default is PASSW0RD (with a zero, not the letter O).
  2. Enter the following command:

    asu set SYSTEM_PROD_DATA.SysInfoSerialNum zzzzzzz     [--user userid][--password password]

    where zzzzzzz is the 7-character serial number of the compute node.

  3. Enter the following command:

    asu set SYSTEM_PROD_DATA.SysEncloseAssetTag aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa     [--user userid][--password password]

    where aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa is the 33-character asset tag number of the compute node.

  4. Restart the IMM.
  5. Restart the server.