Multiple nodes cannot ping the Chassis Management Module in the same chassis

Use the information in this section to troubleshoot multiple nodes that cannot ping the Chassis Management Module on the management network in the same chassis.

Complete the following steps until the problem is solved:
  1. Make sure that the chassis management module is powered on and the applicable ports are enabled on the Chassis Management Module. If the Chassis Management Module is hung, reset the Chassis Management Module.
  2. Reset the Chassis Management Module.
  3. Check for firmware updates for the Chassis Management Module.
  4. Reset the Chassis Management Module to factory defaults and attempt to discover the nodes again. Allow enough time for the IMMs to acquire a network address.
  5. Replace the Chassis Management Module.
  6. Make sure that the compute node IMM has acquired an IP address from the Chassis Management Module by using the Setup utility on the node.
    Note
    If the Chassis Management Module recently lost connection to the DCHP server, you must reset the IMM by using the Chassis Management Module interface so that a new IP address can be acquired.
  7. In the Chassis Management Module user interface, click Chassis Management > Component IP Configuration and make sure that the IP address that is listed is the same as the IP address that is displayed in the Setup utility. If it is not the same IP address, configure the IMM network settings correctly or reset the IMM to automatically acquire a new IP address.
  8. Check the Lenovo Support Portal for any firmware updates that might apply to this problem. You can view the release notes for a firmware update to determine the issues that the update addresses.
  9. Remove the compute node from the chassis and check the connectors on the back of the node for bent pins. If the pins are bent, contact Support.
  10. Check the Lenovo Support Portal for any service bulletins that are related to network connectivity.
  11. (Trained service technician only) Complete the following steps:
    1. Force the link/duplex speed.
    2. Check the connectors on the Chassis Management Module to make sure that no pins are bent.
    3. Check the connectors on the chassis midplane to make sure that no pins are bent.
    4. Remove the Chassis Management Module and install a working Chassis Management Module in the same bay.
    5. If the problem is solved, replace the Chassis Management Module that you removed.