Skip to main content

Server features and specifications

The following information is a summary of the features and specifications of the server. Depending on the model, some features might not be available, or some specifications might not apply.

Table 1. Features and specifications for 4U server models with non-hot-swap power supplies. For the 5U server model with hot-swap power supplies (Model name: 2582-F4x), please see Table 2.

Microprocessor (depending on the model):

  • Supports one Intel quad-core (Xeon E3-1200 series) or dual-core (Pentium G850, or Core i3 series) processor
  • Multi-chip Package processor architecture
  • Designed for LGA 1155 socket
  • Scalable up to four cores
  • 32 KB instruction L1 cache, 32 KB data L1 cache, 256 KB instruction/data L2 cache, and up to 8 MB L3 cache that is shared among the cores
  • Support for Intel Extended Memory 64 Technology (EM64T)
Note
  • Use the Setup utility to determine the type and speed of the microprocessors in the server.
  • For a list of supported microprocessors, see the Lenovo ServerProven website.

Memory:

  • Connectors: four dual inline memory module (DIMM) connectors, two-way interleaved
  • Minimum: 1 GB
  • Maximum: 32 GB
  • Types: PC3-12800 (single-rank or dual-rank), 1066, 1333 and 1600 MHz, ECC, DDR3 unbuffered SDRAM DIMMs only
  • Sizes: 1GB (single-rank) 2GB (single-rank) 4GB (dual-rank) 8GB (dual-rank)

Fan:

  • One system fan

Power supply: One fixed 350-watt or 300-watt power supply

Size:

  • Height: 360 mm (14.17 in.)
  • Depth: 480 mm (18.89 in.)
  • Width: 180 mm (7.08 in.)
  • Weight: 10 kg (22 lb) to 13 kg (28.66 lb) depending upon configuration

RAID (depending on model):

  • ServeRAID-BR10il v2 SAS/SATA adapter that provides RAID levels 0, 1, and 10.
  • ServeRAID-C100 (software RAID) that provides RAID levels 0, 1, and 10.

Environment:

  • Air temperature:
    • Server on: 10°C to 35°C (50°F to 95°F) Altitude: 0 to 914.4 m (3000 ft)
    • Server on: 10°C to 32°C (50°F to 89.6°F) Altitude: 914.4 m (3000 ft) to 2133.6 m (7000 ft)
    • Server on: 10°C to 28°C (50.0°F to 83°F); altitude: 2133.6 m (7000 ft) to 3050 m (10000 ft)
    • Server off: 10°C to 43°C (50°F to 109.4°F)
    • Shipping: -40°C to 60°C (-40°F to 140°F)
  • Humidity (operating and storage): 8% to 80%
  • Particulate contamination:
Attention
Airborne particulates and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the server. For information about the limits for particulates and gases, see Particulate contamination.

Drives (depending on the model):

  • Hard disk drives: up to four 3.5-inch simple-swap SATA
    Note
    3TB hard disk drives are not supported in OS 4690.
  • One of the following SATA attached optical drives:
    • DVD-ROM

Drives bays:

  • Two 5.25-inch half-high bays (one optical drive installed).
  • Four 3.5-inch hard disk drive bays
Attention
As a general consideration, do not mix standard 512-byte and advanced 4-KB format drives in the same RAID array because it might lead to potential performance issues.

Integrated functions:

  • integrated management module II (IMM2), which consolidates multiple management functions in a single chip
  • Intel 82574L Gb Ethernet controller with TCP/IP Offload Engine (TOE) and Wake on LAN support
  • Integrated SATA controller
  • Seven Universal Serial Bus (USB) 2.0 ports (two front, four rear of the chassis, and one internal for an optional tape drive)
  • Six SATA ports (four for simple-swap hard disk drives and two for the DVD drive and the optional tape drive)
  • One serial port
  • Two Ethernet port
  • One VGA port

Heat output: Approximate heat output:

  • Minimum configuration: 119 Btu per hour (35 watts)
  • Maximum configuration: 1194 Btu per hour (350 watts)

Electrical input:

  • Sine-wave input (50 or 60 Hz) required
  • Input voltage and frequency ranges automatically selected
  • Input voltage low range:
    • Minimum: 100 V ac
    • Maximum: 127 V ac
  • Input voltage high range:
    • Minimum: 200 V ac
    • Maximum: 240 V ac
  • Input kilovolt-amperes (kVA) approximately:
    • Minimum: 0.035 kVA (all models)
    • Maximum: 0.350 kVA

Expansion slots:

  • One PCI Express x16 slot
  • One PCI Express x8 slot
  • One PCI Express x4 slot
  • One PCI Express x1 slot

Acoustical noise emissions:

  • Sound power, idling: 4.5 bels
  • Sound power, operating: 4.8 bels
Note
  1. Power consumption and heat output vary depending on the number and type of optional features installed and the power-management optional features in use.
  2. The noise emission level stated is the declared (upper limit) sound power level, in bels, for a random sample of machines. All measurements are made in accordance with ISO 7779 and reported in conformance with ISO 9296.
Table 2. Features and specifications for the 5U server model with hot-swap power supplies (Model name: 2582-F4x). For 4U server models with non-hot-swap power supplies, please see Table 1.

Microprocessor (depending on the model):

  • Supports one Intel quad-core (Xeon E3-1200 series) or dual-core (Pentium G850, or Core i3 series) processor
  • Multi-chip Package processor architecture
  • Designed for LGA 1155 socket
  • Scalable up to four cores
  • 32 KB instruction L1 cache, 32 KB data L1 cache, 256 KB instruction/data L2 cache, and up to 8 MB L3 cache that is shared among the cores
  • Support for Intel Extended Memory 64 Technology (EM64T)
Note
  • Use the Setup utility to determine the type and speed of the microprocessors in the server.
  • For a list of supported microprocessors, see the Lenovo ServerProven website.

Memory:

  • Connectors: four dual inline memory module (DIMM) connectors, two-way interleaved
  • Minimum: 1 GB
  • Maximum: 32 GB
  • Types: PC3-12800 (single-rank or dual-rank), 1066, 1333 and 1600 MHz, ECC, DDR3 unbuffered SDRAM DIMMs only
  • Sizes: 1GB (single-rank) 2GB (single-rank) 4GB (dual-rank) 8GB (dual-rank)

Fan:

  • One system fan

Power supply: One or two redundant 430-watt power supply

Size:

  • Height: 438.60 mm (17.27 in.)
  • Depth: 569.11 mm (22.41 in.)
  • Width: 217.25 mm (8.56 in.)
  • Weight: 19.6 kg (43 lb) to 21.4 kg (47 lb) depending upon configuration

RAID (depending on model):

  • ServeRAID-BR10il v2 SAS/SATA adapter that provides RAID levels 0, 1, and 10.

Environment:

  • Air temperature:
    • Server on: 10°C to 35°C (50°F to 95°F) Altitude: 0 to 914.4 m (3000 ft)
    • Server on: 10°C to 32°C (50°F to 89.6°F) Altitude: 914.4 m (3000 ft) to 2133.6 m (7000 ft)
    • Server on: 10°C to 28°C (50.0°F to 83°F); altitude: 2133.6 m (7000 ft) to 3050 m (10000 ft)
    • Server off: 10°C to 43°C (50°F to 109.4°F)
    • Shipping: -40°C to 60°C (-40°F to 140°F)
  • Humidity (operating and storage): 8% to 80%
  • Particulate contamination:
Attention
Airborne particulates and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the server. For information about the limits for particulates and gases, see Particulate contamination.

Drives (depending on the model):

  • Hard disk drives: up to eight 2.5-inch hot-swap SATA
  • One of the following SATA attached optical drives:
    • DVD-ROM

Drives bays:

  • Two 5.25-inch half-high bays (one optical drive installed).
  • Eight 2.5-inch hard disk drive bays
Attention
As a general consideration, do not mix standard 512-byte and advanced 4-KB format drives in the same RAID array because it might lead to potential performance issues.

Integrated functions:

  • Integrated management module II (IMM2), which consolidates multiple management functions in a single chip
  • Intel 82574L Gb Ethernet controller with TCP/IP Offload Engine (TOE) and Wake on LAN support
  • Integrated SATA controller
  • Seven Universal Serial Bus (USB) 2.0 ports (two front, four rear of the chassis, and one internal for an optional tape drive)
  • Six SATA ports (four for simple-swap hard disk drives and two for the DVD drive and the optional tape drive)
  • One serial port
  • Two Ethernet port
  • One VGA port

Heat output: Approximate heat output:

  • Minimum configuration: 341 Btu per hour (100 watts)
  • Maximum configuration: 1726 Btu per hour (506 watts)

Electrical input:

  • Sine-wave input (50 or 60 Hz) required
  • Input voltage and frequency ranges automatically selected
  • Input voltage low range:
    • Minimum: 100 V ac
    • Maximum: 127 V ac
  • Input voltage high range:
    • Minimum: 200 V ac
    • Maximum: 240 V ac
  • Input kilovolt-amperes (kVA) approximately:
    • Minimum: 0.100 kVA (all models)
    • Maximum: 0.506 kVA

Expansion slots:

  • One PCI Express x16 slot
  • One PCI Express x8 slot
  • One PCI Express x4 slot
  • One PCI Express x1 slot

Acoustical noise emissions:

  • Sound power, idling: 5.0 bels
  • Sound power, operating: 5.3 bels
Note
  1. Power consumption and heat output vary depending on the number and type of optional features installed and the power-management optional features in use.
  2. These levels were measured in controlled acoustical environments according to the procedures specified by the American National Standards Institute (ANSI) S12.10 and ISO 7779 and are reported in accordance with ISO 9296. Actual sound-pressure levels in a given location might exceed the average values stated because of room reflections and other nearby noise sources. The declared sound-power levels indicate an upper limit, below which a large number of computers will operate.
EU Regulation 617/2013 Technical Documentation:

For more information on the energy efficiency program, go to http://www.ibm.com/systems/x/hardware/energy-star/index.html

Product Type:
Computer server
Year first manufactured:
2012
Internal/external power supply efficiency:
Maximum power (watts):
See power supply section.
Idle state power (watts):
83
Sleep mode power (watts):
Not applicable for servers.
Off mode power (watts):
9
Noise levels (the declared A-weighed sound power level of the computer):
See acoustical noise emissions section.
Test voltage and frequency:
230V / 50 Hz or 60 Hz
Total harmonic distortion of the electricity supply system:
The maximum harmonic content of the input voltage waveform will be equal or less than 2%. The qualification is compliant with EN 61000-3-2.
Information and documentation on the instrumentation set-up and circuits used for electrical testing:
ENERGY STAR Test Method for Computer Servers; ECOVA Generalized Test Protocol for Calculating the Energy Efficiency of Internal Ac-Dc and Dc-Dc Power Supplies.
Measurement methodology used to determine information in this document:
ENERGY STAR Servers Version 2.0 Program Requirements; ECOVA Generalized Test Protocol for Calculating the Energy Efficiency of Internal Ac-Dc and Dc-Dc Power Supplies.