Power-supply LEDs
This section describes the power-supply LEDs on the rear of the server and the suggested actions to correct the detected problems.
The following minimum configuration is required for the server to start:
- One microprocessor
- One 1 GB DIMM
- Power supply
- Power cord
- ServeRAID SAS/SATA adapter
- Five cooling fans
The following illustration shows the LEDs and connectors on the rear of the fixed power-supply model.
Figure 1. LEDs and connectors on the rear of the fixed power-supply model
The following illustration shows the LEDs and connectors on the rear of the redundant power-supply model.
Figure 2. LEDs and connectors on the rear of the redundant power-supply model
The following table describes the problems that are indicated by various combinations of the power-supply LEDs and suggested actions to correct the detected problems.
AC Power-supply LEDs | Description | Action | Notes | ||
---|---|---|---|---|---|
AC | DC | Error | |||
On | On | Off | Normal operation | ||
Off | Off | Off | No ac power to the server or a problem with the ac power source. |
| This is a normal condition when no ac power is present. |
On | Off | Off | Faulty system board or faulty power supply |
| Typically indicates that a power supply is not fully seated. This is a normal condition before turning on the system. |
On | Off or Flashing | On | Faulty power supply | Replace the power supply. | |
On | On | On | Power supply is faulty but still operational | Replace the power supply. |