- Microprocessor (depending on the model):
- Support up to two Intel Xeon E5-2600 series multi-core microprocessors with integrated memory controller and Quick Path Interconnect (QPI) architecture
- Up to 2.5M Level-3 cache/core
- Two QuickPath Interconnect (QPI) links speed up to 8.0 GT per second
Note- Use the Setup utility to determine the type and speed of the microprocessors in the server
- For a list of supported microprocessors, see the Lenovo ServerProven website.
- Memory:
- Slot: 12 DIMM connectors (24 DIMM connectors when the microprocessor 2 expansion board is installed)
- Minimum: 2 GB
- Maximum: 768 GB
- 32 GB using unbuffered DIMMs (UDIMMs)
- 384 GB using registered DIMMs (RDIMMs)
- 768 GB using load reduction DIMMs (LRDIMMs)
- Type:
- PC3-8500 (DDR3-1066), PC3-10600 (DDR3-1333), PC3-12800 (DDR3-1600), or PC3-14900 (DDR3-1866)
- Single-rank, dual-rank, or quad-rank
- Registered DIMM (RDIMM), unbuffered DIMM (UDIMM), or load reduced DIMM (LRDIMM)
- Supports (depending on the model):
- 2 GB unbuffered DIMM (UDIMM)
- 2 GB, 4 GB, 8 GB, and 16 GB registered DIMMs (RDIMMs)
- 32 GB load reduction DIMM (LRDIMM)
- Drives:
- SATA:
- DVD-ROM
- Multi-burner
NoteMaximum of two devices can be installed. - Diskette: External USB hard disk drive
- Supported hard disk drives:
- Serial Attached SCSI (SAS)
- Serial ATA (SATA)
- SATA:
- Expansion bays (depending on the model):
- Up to thirty-two 2.5-inch HDD bays
- Up to eight 3.5-inch HDD bays
- Up to two half-high 5.25-inch baysNoteFull-high devices such as an optional tape drive will occupy two half-high 5.25-inch bays.AttentionAs a general consideration, do not mix standard 512-byte and advanced 4-KB format drives in the same RAID array because it might lead to potential performance issues.
- PCI and PCI-X expansion slots:
- Six PCI expansion slots on the system board:
- Slot 1: PCI Express 2.0 x8 (support optional PCI-X interposer card)
- Slot 2: PCI Express 3.0 x8
- Slot 3: PCI Express 3.0 x8
- Slot 4: PCI Express 3.0 x8
- Slot 5: PCI Express 3.0 x16 (support 225W GPU)
- Slot 6: PCI Express 3.0 x8
- Two PCI expansion slots on the microprocessor 2 expansion board:
- Slot 7: PCI Express 3.0 x16 (support 225W GPU)
- Slot 8: PCI Express 3.0 x16
- PCI-X interposer card (optional):
- One PCI-X 64-bit/133 MHz
- Six PCI expansion slots on the system board:
- Power supply (depending on the model):
- Up to two hot-swap power supplies for redundancy support.
- 550-watt ac
- Support up to 95-watt processor.
- Support up to eight HDDs.
- GPU not supported.
- Support up to sixteen 1R/2R RDIMMs or UDIMMs. 4R RDIMMs and LRDIMMs are not supported.
- 550-watt ac
- Up to two hot-swap power supplies for redundancy support.
- 750-watt ac
- Support up to sixteen HDDs.
- GPU not supported.
- Support up to sixteen LRDIMMs, UDIMMs, or twenty-four RDIMMs.
- 900-watt ac
- No GPU installed:
- Hard disk drive:
- Support up to thirty-two HDDs, or,
- Support up to sixteen HDDs if more than sixteen LRDIMMs are installed.
- Memory:
- Support up to sixteen UDIMMs, or,
- Support up to twenty-four RDIMMs/LRDIMMs, or,
- Support up to sixteen LRDIMMs if more than sixteen HDDs are installed.
- Hard disk drive:
- One GPU installed:
- Hard disk drive:
- Support up to eight HDDs.
- Memory:
- Support up to sixteen LRDIMMs/UDIMMs, or,
- Support up to twenty-four RDIMMs.
- Hard disk drive:
- No GPU installed:
- Two 900-watt ac are required and used in non-redundant mode in the following scenarios:
- Two GPUs are installed.
- One GPU is installed and more than eight HDDs are installed.
- One GPU is installed and more than sixteen LRDIMMs are installed.
- More than sixteen HDDs are installed and more than sixteen LRDIMMs are installed.
- 750-watt ac
NotePower supplies in the server must be with the same power rating or wattage.- Up to two hot-swap power supplies for redundancy support.
- Simple-swap fans:
- Two (one microprocessor installed)
- Three (two microprocessors installed)
- Three additional fans (for optional redundant cooling)
- RAID controllers (depending on the model):
- A ServeRAID M1115 SAS/SATA adapter that provides RAID 0, 1, and 10 with optional FoD RAID 5/50 and SED (Self Encrypting Drive) upgrade.
- A ServeRAID M5110 SAS/SATA adapter that provides RAID 0, 1, and 10. Optional upgrade:
- RAID 5/50 (512 MB Cache) with optional FoD RAID 6/60 and SED upgrade
- RAID 5/50 (512 MB Flash) with optional FoD RAID 6/60 and SED upgrade
- RAID 5/50 (1 GB Flash) with optional FoD RAID 6/60 and SED upgrade
- RAID 5/50 and SED (Zero Cache)
- Integrated functions:
- Integrated Management Module II (IMM2), which consolidates multiple management functions in a single chip.
- Intel I350AM4 Quad Port Gigabit Ethernet controller with Wake on LAN support
- Serial over LAN (SOL) and serial redirection over Telnet or Secure Shell (SSH)
- One systems-management 1 Gb Ethernet port for connection to a dedicated systems-management network. This system management connector is dedicated to the IMM2 functions.
- Light path diagnostics
- Six Universal Serial Bus (USB) ports
- Two on front of server
- Four on rear of server
- One internal USB port for optional USB flash device with embedded hypervisor
- One internal USB tape connector
- One serial connector
- Video controller (integrated into IMM2):
- Matrox G200eR2NoteThe maximum video resolution is 1600 x 1200 at 75 Hz.
- SVGA compatible video controller
- DDR3 528 MHz SDRAM video memory controller
- Avocent Digital Video Compression
- 16 MB of video memory (not expandable)
- Matrox G200eR2
- Size:
- Tower
- Height: 440 mm (17.3 in.)
- Depth: 750 mm (29.5 in.)
- Width: 218 mm (8.6 in.)
- Weight: approximately 39.8 kg (87.7 lb) when fully configured or 25.0 kg (55.1 lb) minimum
- Rack
- 5 U
- Height: 218 mm (8.6 in.)
- Depth: 702 mm (27.6 in.)
- Width: 424 mm (16.7 in.)
- Weight: approximately 39.3 kg (86.6 lb) when fully configured or 24.5 kg (54.0 lb) minimum
- Tower
- Acoustical noise emissions:
- Sound power, idling: 6.0 bels
- Sound power, operating: 6.0 bels
- Environment:
- Air temperature:
- Server on: 10°C to 35°C (50.0°F to 95.0°F); altitude: 0 to 915 m (3000 ft)
- Server on: 10°C to 32°C (50.0°F to 90.0°F); altitude: 915 m (3000 ft) to 2134 m (7000 ft)
- Server on: 10°C to 28°C (50.0°F to 83.0°F); altitude: 2134 m (7000 ft) to 3050 m (10000 ft)
- Server off (with standby power): 5°C to 45°C (41°F to 113°F)
- Shipment: -40°C to 60°C (-40°F to 140°F)
- Humidity:
- Server on: 20% to 80%; maximum dew point 21°C; maximum rate of change: 5°C/hour
- Server off (with standby power): 8% to 80%; maximum dew point: 27°C
- Particulate contamination:AttentionAirborne particulates and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the server. For information about the limits for particulates and gases, see
Particulate contamination.
- Air temperature:
- Heat output:
Approximate heat output:
- Minimum configuration: 2013 Btu per hour (590 watts)
- Maximum configuration: 3610 Btu per hour (1058 watts)
- Electrical input:
- Sine-wave input (50-60 Hz) required
- Input voltage low range:
- Minimum: 100 V AC
- Maximum: 127 V AC
- Input voltage high range:
- Minimum: 200 V AC
- Maximum: 240 V AC
- Input kilovolt-amperes (kVA), approximately:
- Minimum: 0.60 kVA
- Maximum: 1.10 kVA
Note
- Power consumption and heat output vary depending on the number and type of optional features installed and the power-management optional features in use.
- The noise emission level stated is the declared (upper limit) sound power level, in bels, for a random sample of machines. All measurements are made in accordance with ISO 7779 and reported in conformance with ISO 9296.
- EU Regulation 617/2013 Technical Documentation:
- International Business Machines Corporation
- New Orchard Road
- Armonk, New York 10504
- http://www.ibm.com/customersupport/
For more information on the energy efficiency program, go to http://www.ibm.com/systems/x/hardware/energy-star/index.html.
- Product Type:
- Computer server
- Year first manufactured:
- 2012
- Internal/external power supply efficiency:
- http://www.plugloadsolutions.com/psu_reports/IBM_FSA011_550W_SO-301_Report.pdf
- http://www.plugloadsolutions.com/psu_reports/IBM_7001676-XXXX_550W_SO-458_Report.pdf
- http://www.plugloadsolutions.com/psu_reports/IBM_7001605-XXXX_750W_SO-258_Report.pdf
- http://www.plugloadsolutions.com/psu_reports/SO-299_IBM_DPS-750AB-1_750W_Report.pdf
- http://www.plugloadsolutions.com/psu_reports/IBM_DPS-750AB-14%20A_750W_SO-527_Report.pdf
- http://www.plugloadsolutions.com/psu_reports/IBM_7001606-XXXX_900W_SO-273_Report.pdf
- http://www.plugloadsolutions.com/psu_reports/IBM_DPS-900CB%20A_900W_SO-440_Report.pdf
- Maximum power (watts):
- See Power supply.
- Idle state power (watts):
- 97
- Sleep mode power (watts):
- Not applicable for servers
- Off mode power (watts):
- 19
- Noise levels (the declared A-weighed sound power level of the server)
- See Acoustical noise emissions.
- Test voltage and frequency:
- 230V / 50 Hz or 60 Hz
- Total harmonic distortion of the electricity supply system:
- The maximum harmonic content of the input voltage waveform will be equal or less than 2%. The qualification is compliant with EN 61000-3-2.
- Information and documentation on the instrumentation setup and circuits used for electrical testing:
- ENERGY STAR Test Method for Computer Servers; ECOVA Generalized Test Protocol for Calculating the Energy Efficiency of Internal Ac-Dc and Dc-Dc Power Supplies
- Measurement methodology used to determine information in this document:
- ENERGY STAR Servers Program Requirements; ECOVA Generalized Test Protocol for Calculating the Energy Efficiency of Internal Ac-Dc and Dc-Dc Power Supplies