W.50001 : A DIMM has been disabled due to an error detected during POST. DIMM Disabled
A DIMM has been disabled due to an error detected during POST. DIMM Disabled
Severity
Info
User Response
Complete the following steps:
- If the DIMM was disabled because of a memory fault, follow the procedure for that event.
- If no memory fault is recorded in the logs and no DIMM connector error LEDs are lit, re-enable the DIMM through the Setup utility or the ToolsCenter Suite CLI.
- If the problem persists, Power cycle the compute node from the management console.
- Reset the IMM to default settings.
- Reset UEFI to default settings.
- Update IMM and UEFI firmware.
- Swap/reseat the DIMM from the disabled slot with a matching DIMM. If the slot remains disabled, (trained technician only) replace system board
Give feedback