80010902-0701ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted. (SysBrd 12V)
Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted. (SysBrd 12V)
This message is for the use case when an implementation has detected an Upper Critical sensor going high has asserted.
May also be shown as 800109020701ffff or 0x800109020701ffff
Severity
Error
Alert Category
Critical - Voltage
Serviceable
Yes
SNMP Trap ID
1
Automatically Notify Support
Yes
User Response
If the specified sensor is Planar 3.3V or Planar 5V, (trained technician only) replace the system board. If the specified sensor is Planar 12V, complete the following steps until the problem is solved:
- Check power supply n LED.
- Remove the failing power supply.
- (Trained technician only) Replace the system board. (n = power supply number)