180-901-000 : Check-point Panel Test Failed
Check-point Panel Test Failed
Severity
Error
Serviceable
Yes
Recoverable
No
Automatically Notify Support
No
User Response
Complete the following steps:
- Check the operator information panel cabling for loose or broken connections at both ends or damage to the cable.
- Replace the information panel cable if damage is present.
- Run the test again.
- Replace the operator information panel assembly.
- Run the test again.
- If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
Related Links
Feedback geben