GET – Chassis properties
Use the GET method to retrieve properties in Chassis resource for a server.
Request URL
GET https://<BMC_IPADDR>/redfish/v1/Chassis/1
Request body
None
Response body
Field | Type | Description | |||
---|---|---|---|---|---|
AssetTag | String | The user assigned asset tag for this chassis. | |||
ChassisType | String | This property indicates the type of physical form factor of this resource. Valid values include:
| |||
Description | String | Provides a description of this chassis resource. | |||
EnvironmentalClass | String | The ASHRAE Environmental Class for this chassis. | |||
HeightMn | Number | The height of the chassis. | |||
Id | String | Uniquely identifies the resource within the collection of Chassis. For the Chassis resource for the server, the Id is “1”. | |||
IndicatorLED | String | The state of the indicator LED, used to identify the chassis. Valid values include:
| |||
PCIeDevices | Link | A reference link to the PCIe devices located in this chassis. | |||
Links | Object | Expanded. | |||
ComputerSystems | Array | An array of references to the computer systems contained in this chassis. | |||
ComputerSystems[0] | Link | A reference link to a resource of computer system. | |||
Fans | Array | An array of IDs of resources that cool this chassis. | |||
Fans[0] | Link | A reference link to a resource of cooling device. | |||
Drives | Array | An array of resources to disk drives of in this chassis. | |||
ManagedBy | Array | An array of references to the managers responsible for managing this chassis. | |||
ManagedBy[0] | Link | A reference link to a resource of manager responsible for managing this chassis. | |||
ManagersInChassis | Array | An array of references to the managers contained in this chassis. | |||
ManagerInChassis[0] | Link | A reference link to a resource of manager. | |||
PCIeDevices | Array | An array of references to the PCIe devices located in this chassis. | |||
PCIeDevices[N] | LInk | A reference link to a resource of PCIe device located in this chassis. | |||
PowerSupplies | Array | An array of IDs of resources that power this chassis. | |||
PowerSupplies[N] | Link | A reference link to a resource of power device. | |||
Processors | Array | An array of references to the processors located in this chassis. | |||
Processors[N] | Link | A reference link to a resource of processors located in this chassis. | |||
Storage | Array | An array of references to the storage subsystems connected to or inside this chassis. | |||
Storage[N] | Link | A reference link to a resource of storage device inside this chassis. | |||
Location | Object | The location of chassis. | |||
Contacts | Array | An array of contact information. | |||
Contacts[0] | Object | Expanded. | |||
ContactName | String | Name of this contact. | |||
PartLocation | Object | The part location within the placement. | |||
Placement | Object | A place within the addressed location. | |||
Rack | String | The name of a rack location within a row. | |||
RackOffset | Integer | The vertical location of the item, in terms of RackOffsetUnits. | |||
RackOffsetUnits | String | The type of rack units in use. | |||
PostalAddress | Object | The postal address of the addressed Resource. | |||
Building | String | The name of the building. | |||
Location | String | The room designation or other additional information. | |||
Name | String | The name of the system. | |||
Room | String | The name or number of the room. | |||
LogServices | Link | A reference link to the log services resource contained in this chassis. | |||
Manufacturer | String | The manufacturer of this chassis. Always set to Lenovo or LNVO. | |||
Model | String | The model number for the chassis. | |||
Name | String | The name of the Chassis resource. Always set to “Chassis”. | |||
NetworkAdapters | Link | A reference link to a collection of network adapter resources contained in this chassis. | |||
PartNumber | String | The part number of this chassis. | |||
PCIeSlots | Link | A reference link to a collection of PCIe slot resources contained in this chassis. | |||
Power | Link | A reference link to a resource of power device contained in this chassis. | |||
PowerState | String | The current power state of this chassis. Valid values include:
| |||
SKU | String | The SKU for this chassis. | |||
Sensors | Link | A reference link to the sensor resource contained in this chassis. | |||
SerialNumber | String | The serial number of this chassis. | |||
Status | Object | Contains the following elements. | |||
Health | String | The current health of this chassis as indicated by the entries in the event log. Valid values include:
| |||
HealthRollup | String | This represents the health state of this resource and its dependent resources. | |||
Thermal | Link | A reference link to the thermal resource contained in this chassis. | |||
UUID | String | The UUID for this chassis. | |||
Memory | Link | A reference link to the memory resources located in this chassis. | |||
ThermalSubsystem | Link | A reference link to the thermal subsystem resources located in this chassis. | |||
PowerSubsystem | Link | A reference link to the power subsystem resources located in this chassis. | |||
Controls | Link | A reference link to the controls resources located in this chassis. | |||
EnvironmentMetrics | Link | A reference link to the environment metrics resources located in this chassis. | |||
Version | String | The version for this chassis. | |||
Oem | Object | Expanded. | |||
Lenovo | Object | Expanded. | |||
FanSpeedBoost | String | The value is either “Normal”, “Low”, “Medium”, “High” or “Unknown”. |
Status code
HTTP Status Code | Error Message ID |
---|---|
500 | InternalError |
Example
The following example JSON response is returned:
{
"@odata.context": "/redfish/v1/$metadata#Chassis.Chassis",
"@odata.etag": "\"53E44803\"",
"@odata.id": "/redfish/v1/Chassis/1",
"@odata.type": "#Chassis.v1_21_0.Chassis",
"AssetTag": "",
"ChassisType": "RackMount",
"Controls": {
"@odata.id": "/redfish/v1/Chassis/1/Controls"
},
"Description": "This resource is used to represent a chassis or other physical enclosure for a Redfish implementation.",
"EnvironmentMetrics": {
"@odata.id": "/redfish/v1/Chassis/1/EnvironmentMetrics"
},
"EnvironmentalClass": "A4",
"HeightMm": 88.9,
"Id": "1",
"IndicatorLED": "Off",
"Links": {
"ComputerSystems": [
{
"@odata.id": "/redfish/v1/Systems/1"
}
],
"Drives": [
{
"@odata.id": "/redfish/v1/Systems/1/Storage/controller_slot8/Drives/drive_bay_0"
},
{
"@odata.id": "/redfish/v1/Systems/1/Storage/controller_slot8/Drives/drive_bay_1"
}
],
"Fans": [
{
"@odata.id": "/redfish/v1/Chassis/1/ThermalSubsystem/Fans"
}
],
"ManagedBy": [
{
"@odata.id": "/redfish/v1/Managers/1"
}
],
"ManagersInChassis": [
{
"@odata.id": "/redfish/v1/Managers/1"
}
],
"PCIeDevices": [
{
"@odata.id": "/redfish/v1/Chassis/1/PCIeDevices/slot8_0xc60000"
},
{
"@odata.id": "/redfish/v1/Chassis/1/PCIeDevices/slot3_0xb0000"
} ],
"PowerSupplies": [
{
"@odata.id": "/redfish/v1/Chassis/1/PowerSubsystem/PowerSupplies/PSU1"
},
{
"@odata.id": "/redfish/v1/Chassis/1/PowerSubsystem/PowerSupplies/PSU2"
}
],
"Processors": [
{
"@odata.id": "/redfish/v1/Systems/1/Processors/2"
},
{
"@odata.id": "/redfish/v1/Systems/1/Processors/1"
}
],
"Storage": [
{
"@odata.id": "/redfish/v1/Systems/1/Storage/controller_slot8"
}
]
},
"Location": {
"Contacts": [
{
"ContactName": ""
}
],
"PartLocation": {},
"Placement": {
"Rack": "",
"RackOffset": 1,
"RackOffsetUnits": "EIA_310"
},
"PostalAddress": {
"Building": "",
"Location": "",
"Name": "",
"Room": ""
}
},
"LogServices": {
"@odata.id": "/redfish/v1/Systems/1/LogServices"
},
"Manufacturer": "Lenovo",
"Memory": {
"@odata.id": "/redfish/v1/Systems/1/Memory"
},
"Model": "7DGCCTO1WW",
"Name": "Chassis",
"NetworkAdapters": {
"@odata.id": "/redfish/v1/Chassis/1/NetworkAdapters"
},
"Oem": {
...
}
},
"PCIeDevices": {
"@odata.id": "/redfish/v1/Chassis/1/PCIeDevices"
},
"PCIeSlots": {
"@odata.id": "/redfish/v1/Chassis/1/PCIeSlots"
},
"PartNumber": "SB27C00442",
"Power": {
"@odata.id": "/redfish/v1/Chassis/1/Power"
},
"PowerState": "On",
"PowerSubsystem": {
"@odata.id": "/redfish/v1/Chassis/1/PowerSubsystem"
},
"SKU": "7DGCCTO1WW",
"Sensors": {
"@odata.id": "/redfish/v1/Chassis/1/Sensors"
},
"SerialNumber": "BHSFW2U005",
"Status": {
"Health": "OK",
"HealthRollup": "OK",
"State": "Enabled"
},
"Thermal": {
"@odata.id": "/redfish/v1/Chassis/1/Thermal"
},
"ThermalSubsystem": {
"@odata.id": "/redfish/v1/Chassis/1/ThermalSubsystem"
},
"UUID": "FE57AA52-E969-4448-9C0B-045179900052",
"Version": "5"
}