Not all storage drives are recognized by the Fixed Disk or SAS Attached Disk diagnostic test. | - Remove the storage drive that is indicated by the diagnostic tests. See Removing and replacing blade server components.
- Run the SAS Fixed Disk or SAS Attached Disk diagnostic test again. See Diagnostic tools.
- If the Fixed drive or SAS Attached Disk diagnostic test runs successfully, replace the storage drive that you removed with a new one. See Removing and replacing blade server components.
|
The blade server stops responding during the Fixed Disk or SAS Attached Disk diagnostic test. | - Remove the storage drive that was being tested when the blade server stopped responding. See Removing and replacing blade server components.
- Run the SAS Fixed Disk or SAS Attached Disk diagnostic test again. See Diagnostic tools.
- If the Fixed drive or SAS Attached Disk diagnostic test runs successfully, replace the storage drive that you removed with a new one. See Removing and replacing blade server components.
|
A storage drive passes the Fixed Disk or SAS Attached Disk diagnostics test, but the problem remains. | - Run the SAS Fixed Disk or SAS Attached Disk diagnostic test again. See Diagnostic tools.
- If the Fixed drive or SAS Attached Disk diagnostic test runs successfully but the storage drive continues to have a problem, replace the drive with a new one.
|