Broadcom Ethernet device tests
Use this information to resolve Broadcom Ethernet device errors.
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
| ||
---|---|---|
Error code | Description | Action |
405-000-xxx | Passed the ControlRegisters test. | N/A |
405-901-xxx | Failed the ControlRegisters test. A failure was detected while testing internal MAC registers. |
|
405-001-xxx | Passed the MIIRegisters test. | N/A |
405-901-xxx | Failed the MIIRegisters test. A failure was detected while testing internal PHY registers. |
|
405-002-xxx | Passed the EEPROM test. | N/A |
405-902-xxx | Failed the EEPROM test. A failure was detected while testing non-volatile RAM. |
|
405-003-xxx | Passed the InternalMemory test. | N/A |
405-903-xxx | Failed the InternalMemory test. A failure was detected while testing internal memory. |
|
405-004-xxx | Passed the Interrupt test. | N/A |
405-904-xxx | Failed the Interrupt test. A failure was detected while testing interrupts. |
|
405-005-xxx | Passed the LoopbackAtMACLayer test. | N/A |
405-905-xxx | Failed the LoopbackAtMACLayer test. A failure was detected during the loopback test at the MAC layer. |
|
405-006-xxx | Passed the LoopbackAtPhysicallayer test. | N/A |
405-906-xxx | Failed the LoopbackAtPhysicallayer test. A failure was detected during the loopback test at the physical layer. |
|
405-006-xxx | Passed the LEDs test. | N/A |
405-906-xxx | Failed the LEDs test. A failure was detected while verifying operation of the status LEDs. |
|