Microprocessor: Supports up to two multi-core IntelXeon microprocessors. Use the Setup utility to determine the type and speed of the microprocessors in the blade server. Memory:- 12 dual inline memory module (DIMM) connectors
 - Type: Very Low Profile (VLP) double-data rate (DDR3) single-rank, dual-rank, or quad-rank DRAM
 - Supports 2 GB, 4 GB, 8 GB, and 16 GB DIMMs with up to 192 GB of total memory on the system board
 
  Integrated functions:- Horizontal-compact-form-factor (CFFh) expansion card interface
 - Vertical-combination-I/O (CIOv) expansion card interface
 - Local service processor: Integrated Management Module II (IMM2) with Intelligent Platform Management Interface (IPMI) firmware
 - Integrated Renesas SH7757 IMM2 video controller
 - Integrated keyboard/video/mouse (cKVM) controller through the IMM2
 - Light path diagnostics
 - RS-485 interface for communication with the management module
 - USB 2.0 for communication with cKVM and removable media drives (an external USB port is not supported)
 - Serial over LAN (SOL)
 - Wake on LAN (WOL)
 - Redundant buses for communication with keyboard, mouse, and removable media drives
 
   | Predictive Failure Analysis (PFA) alerts:- Memory
 - Storage drives (SAS only)
 
  Electrical input: 12 V dc Environment: - Air temperature:
- Blade server on: 10°C to 35°C (50°F to 95°F). Altitude: 0 m to 914.4 m (0 ft to 3000 ft)
 - Blade server on: 10°C to 32°C (50°F to 89.6°F). Altitude: 914.4 m to 2133.6 m (3000 ft to 7000 ft)
 - Blade server off: 10°C to 43°C (50°F to 109.4°F). Altitude: 914.4 m to 2133.6 m (3000 ft to 7000 ft)
 - Blade server shipping: -40°C to 60°C (-40°F to 140°F)
 
  - Humidity:
- Blade server on: 8% to 80%
 - Blade server off: 8% to 80%
 - Blade server storage: 5% to 80%
 - Blade server shipment: 5% to 100%
 
  - Particulate contamination:
Airborne particulates and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the server. For information about the limits for particulates and gases, see  Particulate contamination. 
  | Drives: Supports up to two hot-swap, small form factor (SFF) - Serial Attached SCSI (SAS) (enabled when ServeRAID H1135 is installed)
 - Serial ATA (SATA) (including solid-state storage drives)
 
  Size:- Height: 24.5 cm (9.64 inches) (6U)
 - Depth: 44.6 cm (17.56 inches)
 - Width: 2.9 cm (1.14 inches)
 - Maximum weight: 4.63 kg (10.2 lb)
 
   |