coolingzones command

This command displays Lenovo Flex System chassis cooling zone and fan module health information.

Note
If one or more fan modules in a cooling zone are missing, the components installed in that cooling zone might not cool sufficiently. Check the CMM event log for temperature event messages using the displaylog command.

If command syntax is not correctly entered, or if a command fails to run, an error message is returned. See Common errors for a list of error messages that apply to all commands or coolingzones command errors for a list of error messages that are specific to the coolingzones command.

Table 1. coolingzones command.

The command table is a multi-row, four-column table where each row describes a CMM CLI command option: column one lists command function, column two provides a detailed command description, column three shows command-option syntax, and column four lists valid command targets.

FunctionWhat it doesCommandTarget (see paths in Command targets)
Display cooling zone informationDisplay information for all cooling zones in the Lenovo Flex System chassis.coolingzones
Lenovo Flex System chassis:
  • system
Display specific cooling zone informationDisplays detailed information for the specified cooling zone.coolingzones z zone

where zone is the cooling zone index number to display.

Valid cooling zone index numbers can be seen by running the coolingzones command with no argument.

Lenovo Flex System chassis:
  • system
Example: To display cooling zone information for all cooling zones, while the chassis is set as the persistent command environment, at the system> prompt, type
coolingzones
To display cooling zone information for cooling zone 2, while the chassis is set as the persistent command environment, at the system> prompt, type
coolingzones z2

The following example shows the information that is returned from these commands:

system> coolingzones

Zone 1:
-------
Status: ok
Provider(s):
blower[1]
blower[2]
blower[3]
blower[4]
Receiver(s):
blade[5],blade[11]

Zone 2:
-------
Status: warning
Provider(s):
blower[6] not present
blower[7]
blower[8]
blower[9]
Receiver(s):
blade[4]

Zone 3:
-------
Status: warning
Provider(s):
blower[5] not present
Receiver(s):
mm[1]
switch[2]

Zone 4:
-------
Status: ok
Provider(s):
blower[10]
Receiver(s):
switch[1],switch[3]

system> coolingzones z2

Status: warning

Cooling Provider(s):
--------------------

blower[6]: not present
blower[7]:
Status: ok
Count: 1
Speed: 38%
Avg RPM: 4352
Controller State: Operational
blower[8]:
Status: ok
Count: 1
Speed: 38%
Avg RPM: 4352
Controller State: Operational
blower[9]:
Status: ok
Count: 1
Speed: 38%
Avg RPM: 4416
Controller State: Operational

Cooling Receiver(s):
--------------------

blade[4]

system>