Command reference
Each command topic describes an Lenovo Flex SystemChassis Management Module 2 command-line interface command, providing information about its function, syntax, and usage, with examples.
Adding a -h, -help, or ? option to a command displays syntax help for that command. For example, to display help for the environment command, type one of the following commands:
- env -h
- env -help
- env ?
You can target a command to a device other than the one that is set as the default by adding a -T option to a command. See Command targets for information.
Commands are listed in alphabetic order.
- accesscontrol command
This command displays and configures user access policies based on IP/MAC. - accseccfg command
This command displays and configures user account security settings for the CMM, including password policies. - advfailover command
This command displays and configures the advanced failover settings for the CMM. - airfilter command
This command sets the interval for air filter change notifications. - alarm command
This command acknowledges or unacknowledges alarms, clears alarms, or creates custom alarms for the specified command target. - alertcfg command
This command displays and configures the global remote alert settings for the CMM. - alertentries command
This command manages the recipients of alerts generated by the primary CMM. - autoftp command
This command displays and configures the automated FTP/TFTP/SFTP problem report settings for the CMM. - baydata command
This command allows a user to set, assign, and display informational data assigned to the compute node bays. - bootmode command
This command sets and displays the boot mode settings for compute nodes installed in the Lenovo Flex System chassis that support this feature. - bootseq command
This command sets and displays the boot sequence settings for compute nodes installed in the Lenovo Flex System chassis. - chconfig command
This command configures the Lenovo Flex System chassis Service Advisor feature. - chlog command
This command is used to display up to five call-home activity log entries and to mark a call-home event entry as acknowledged or unacknowledged. - chmanual command
This command tests the Lenovo Flex System chassis call-home feature setup. - cimsub command
This command displays and clears subscriptions for the common information model (CIM) used by the optional Lenovo XClarity Administrator or Flex System Manager software. - cin command
This command can be used to view and configure the chassis internal network for up to 14 supported chassis internal network (CIN) configurations, globally, or for specified entries. You can define a CIN by creating a pool of VLAN (virtual local area network) ID/IP address pairs, each of which is a CIN entry. - cinstatus command
This command displays a table listing the VLAN ID, the IP address, the MAC address, and the status of each chassis internal network (CIN) connection. - clear command
This command restores the primary CMM configuration or an I/O (switch) module configuration to the manufacturing default settings. - clearlog command
This command clears the CMM audit event log, the system event log, or both. - config command
This command sets and displays the name of the CMM or compute node and the location and contact name for the CMM. - console command
This command sets up a serial over LAN connection to the command console of a compute node. - coolingzones command
This command displays Lenovo Flex System chassis cooling zone and fan module health information. - crypto command
This command displays and configures the cryptographic settings for the CMM. These settings are required to achieve National Institute of Standards and Technology (NIST) compatibility. - date command
This command configures and displays the CMM date settings. - dhcpinfo command
This command displays the IP configuration that is assigned by a DHCP server to the primary CMM external network interface, compute node management network interfaces, and I/O module DHCPv6 server. - displaylog command
This command displays CMM event log entries. - displaysd command
This command captures service data for users to download. - dns command
This command configures and displays the CMM DNS settings. - env command
This command sets the persistent environment for commands that are entered during the remainder of the current session. - ethoverusb command
This command sets and displays the setting for the Ethernet-over-USB command interface of a compute node system-management processor, for compute nodes that support this feature. - events command
This command manages the Call Home events exclusion list for the CMM. - exit command
This command exits the command-line interface, terminating the current session. - files command
This command manages files uploaded to the CMM. - fod command
This command displays licensing information for optional Lenovo Flex SystemCMM and I/O module Features on Demand features. - fruactlog command
This command displays a summary of the hardware activity for modules installed in the Lenovo Flex System chassis. - fsmcm command
This command disables centralized user account management from an optional management device, such as the Lenovo XClarity Administrator or Flex System Manager management software, allowing use of local CMM user accounts. - fuelg command
This command displays power domain information, listing the power supplies that are installed in the Lenovo Flex System chassis and information about power usage. This command also configures policies for power redundancy loss and limiting fan noise during thermal events. - groups command
This command displays and configures Active Directory groups of the primary CMM. This group information is used only when LDAP servers are enabled for authentication with local authorization. - health command
This command displays the current health status of the command target. It can also be used to display the alerts that are active for the command target. - help command
This command displays a list of all commands that are available in the command-line interface with a brief description of each command. - history command
This command displays the last eight commands that were entered, allowing the user to choose and re-enter one of these commands. - ifconfig command
This command configures and displays the network interface settings for the CMM Ethernet interface, I/O-module Ethernet interface, and the compute node system-management processors and installed options. - info command
This command displays information about Lenovo Flex System components and their configuration. - iocomp command
This command displays the compatibility between all compute nodes and their I/O modules. It can also display detailed interface information for an individual compute node or I/O module. - ldapcfg command
This command sets and displays the LDAP configuration settings for the CMM. - led command
This command displays and sets the LED states for a specified command target, if this command target supports the LED. - list command
This command displays a list of devices present within the command target. It can be used to determine the physical configuration of the Lenovo Flex System chassis, including how many CMMs are installed in the Lenovo Flex System chassis and which CMM is set as primary. - monalerts command
This command displays and configures alerts that are monitored by the CMM. - ntp command
This command configures and displays the CMM network time protocol (NTP) settings. - permgroups command
This command displays and configures user permission groups of the primary CMM. - ping command
This command tests the internal communication path between the CMM and an Lenovo Flex System component by sending it a ping request. - pmpolicy command
This command displays and sets the power management policies for the Lenovo Flex System chassis. - portcfg command
This command configures and displays the settings for the CMM serial port. - ports command
This command sets and displays the network port configuration settings for the CMM and I/O modules. - power command
This command turns on and turns off compute nodes and I/O modules. - pwrprofile command
This command displays and configures power groups and schedules for compute nodes and I/O modules. - read command
This command restores the CMM configuration, including users and permission groups, that was previously saved to a file. It can also be used to unmanage the CMM after a failed or incomplete unmanage operation. - remotechassis command
This command displays and manages the list of each Lenovo Flex System chassis that the CMM discovers on the network. - reset command
This command resets compute nodes, compute node system-management processors, I/O modules, or the primary CMM. It also resets the multiplexer expansion module. - scale command
This command displays the partition control and configuration settings for multiple compute nodes or nodes in a scalable complex, for compute nodes installed in the Lenovo Flex System chassis that support this feature. - sddump command
This command initiates a dump of service data from compute nodes, and I/O modules that support this function. - sdemail command
This command sends an email with the service information to the specified recipients. - security command
This command sets and displays the chassis security policy level for the CMM. - service command
This command resets a compute node, compute node system-management processor, I/O module, or the primary or standby CMM. - smtp command
This command configures and displays the CMM SMTP settings. - snmp command
This command configures and displays the CMM SNMP settings. - sol command
This command configures SOL (serial over LAN) functions and indicates SOL status. - sshcfg command
This command sets and displays the SSH and SFTP status of the CMM. - sslcfg command
This command sets and displays the Secure Sockets Layer (SSL) status of the CMM. - syslog command
This command manages how the CMM handles transmission of event log messages to networked syslog event collectors. - tcpcmdmode command
This command displays and changes the timeout of the TCP command-mode sessions that are used by optional management devices, such as the Lenovo XClarity Administrator or Flex System Manager software, for out-of-band communication with the CMM. This command is also used to enable or disable the TCP command-mode sessions. - temps command
This command displays actual temperatures and temperature threshold values for Lenovo Flex System components. - trespass command
This command sets and displays the status and message for the CMM trespass feature that can display a warning message to users when they log in. - uicfg command
This command displays and configures the CMM user interface settings. - update command
This command updates firmware using the uniform resource locator (URL) of a TFTP, FTP, HTTP, HTTPS, or SFTP server and displays information about firmware installed in Lenovo Flex System components. - uplink command
This command displays and configures the CMM uplink failover feature. If the external network interface of the primary CMM fails, this feature forces a failover to the standby CMM, if one is installed. - users command
This command displays and configures user accounts, also called user profiles, of the primary CMM. - vlan command
This command configures and displays the VLAN (virtual local area network) settings for the CMM. - volts command
This command displays actual voltages and voltage threshold values for Lenovo Flex System components. - write command
This command saves the CMM configuration, including user accounts and permission groups, to a file.
Give documentation feedback