800b0509-1301ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has asserted. (Power Resource)
Non-redundant:Insufficient Resources for [RedundancySetElementName] has asserted. (Power Resource)
This message is for the use case when a Redundancy Set has transitioned to Non-redundant:Insufficient Resources.
May also be shown as 800b05091301ffff or 0x800b05091301ffff
Severity
Error
Alert Category
Critical - Redundant Power Supply
Serviceable
Yes
SNMP Trap ID
9
Automatically Notify Support
No
User Action
- Power load may be handled by remaining power supply. The system will attempt to throttle to avoid a power supply over-current condition. But a system shutdown may happen anyway if the power load is too great.
- Reduce the total power consumption by removing newly added or unused options like drives or adaptors.
- Use the Lenovo Power Configurator utility to determine current system power consumption. For more information and to download the utility, go to https://www.ibm.com/support/entry/myportal/docdisplay?lndocid=LNVO-PWRCONF.
- Replace the power supply with higher rated power if Oversubscription_Fault seen in power supply.
- Please reseat power cords and power supplies.
Give documentation feedback