806f0a0c-200fffff : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 15)
An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 15)
This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.
May also be shown as 806f0a0c200fffff or 0x806f0a0c200fffff
Severity
Error
Alert Category
Critical - Temperature
Serviceable
Yes
SNMP Trap ID
0
Automatically Notify Support
No
User Action
- Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in place and correctly installed, and that the server cover is installed and completely closed.
- Make sure that ambient temperature is within the specifications.
- If a fan has failed, complete the action for a fan failure.
- Replace DIMM n. (n = DIMM number)
Give documentation feedback