Server features and specifications
The following information is a summary of the features and specifications of the server. Depending on the model, some features might not be available, or some specifications might not apply.
- Microprocessor (depending on the model):
- Supports up to two Intel Xeon™ E5-2600 v4 series multi-core microprocessors (one installed)
- Two QuickPath Interconnect (QPI) links speed up to 9.6 GT per second
Note- Use the Setup Utility program to determine the type and speed of the microprocessors.
- For a list of supported microprocessors, see the Lenovo ServerProven website.
- Memory (depending on the model):
- Minimum: 128 GB
- Maximum: 1536 GB
- Type:
- PC4-19200 (DDR4-2400), operating speed depends on memory population
- Dual-rank
- Registered DIMM (RDIMM) or LRDIMMRegistered DIMM (RDIMM) or load reduced DIMM (LRDIMM)
- Slots: 24 dual inline
- Supports (depending on the model):
- 16 GB and 32 GB RDIMMs
64 GB LRDIMMs
- Integrated functions:
- Integrated management module 2.1 (IMM2.1), which consolidates multiple management functions in a single chip.
- Broadcom BCM5719 Quad Port Gigabit Ethernet controller with Wake on LAN support
- Up to six Universal Serial Bus (USB) connectors (depending on the model)
- Three USB 2.0 connectors on the front of the chassis
- Two USB 3.0 connectors on the rear of the chassis
- One internal USB 2.0 connector
- Four network ports (four 1 Gb Ethernet ports on the system)
- One System Management RJ-45 on the rear to connect to a systems management network. This system management connector is dedicated to the IMM2.1 functions.
- Optional serial port
- Hard disk drive expansion bays (depending on the model):
- 2.5-inch models:
- Supports eight or twenty-four 2.5-inch hot-swap SATA hard disk drive bays.
- 3.5-inch models:
- Supports eight 3.5-inch hot-swap SAS hard disk drive bays.
- 2.5-inch models:
- HBA controllers:
- N2215 SAS/SATA HBA (supporting one or three depending on model)
- Video controller (integrated into IMM2.1):
- Matrox G200eR2NoteThe maximum video resolution is 1600 x 1200 at 75 Hz.
- SVGA compatible video controller
- DDR3 528 MHz SDRAM video memory controller
- Avocent Digital Video Compression
- 16 MB of video memory (not expandable)
- Matrox G200eR2
- Size (2U):
- Height: 86.5 mm (3.406 inch)
- Depth: EIA flange to rear - 755 mm (29.724 inch), Overall - 800 mm (31.496 inch)
- Width: With top cover - 445.6 mm (17.543 inch), With EIA - 482.0 mm (18.976 inch)
- Weight: approximately 28 kg (62 lb) to 34 kg (75 lb) depending upon configuration
- PCI expansion slots:
- Riser-card assembly 1 (for HX3510-G and HX7510)
- Slot 1: PCI Express 3.0 x16 (full-height, full-length)
- Slot 2: Not available
- Slot 3: PCI Express 3.0 x8 (full-height, half-length)
PCI expansion slots 4- Slot 4: PCI Express 3.0 x8 (low-profile)
PCI expansion slots 5- Slot 5: PCI Express 3.0 x16 (low-profile)
Riser-card assembly 2 (for HX3510-G and HX7510)- Slot 6: PCI Express 3.0 x16 (full-height, full-length)
- Slot 7: Not available
- Slot 8: PCI Express 3.0 x8 (full-height, half-length)
- Electrical input:
- Sine-wave AC input (50/60 Hz) required
- For 900W AC Platinum power supplies:
- Input voltage low range:
- Minimum: 100 Vac
- Maximum: 127 Vac
- Input voltage high range:
- Minimum: 200 Vac
- Maximum: 240 Vac
- Input voltage low range:
- For 1500W Platinum power supplies:
- Input voltage range:
- Minimum: 200 Vac
- Maximum: 240 Vac
- Input voltage range:
Maximum Input kilovolt-amperes (kVA), approximately:- The Minimum Configuration: 0.093 kVA
- The Maximum Configuration: 1.967 kVA
Note- Power consumption and heat output vary depending on the number and type of optional features installed and the power-management optional features in use.
- The noise emission level stated is the declared (upper limit) sound power level, in bels, for a random sample of machines. All measurements are made in accordance with ISO 7779 and reported in conformance with ISO 9296. Actual sound-pressure levels in a given location might exceed the average values stated because of room reflections and other nearby noise sources. The noise emission level stated in the declared (upper limit) sound-power level, in bels, for a random sample of system.
- For 900W AC Platinum power supplies:
- Hot-swap fans:
- Two microprocessors: six single-motor hot-swap fans
NoteYour server supports single-motor fans only. On the integrated management module (IMM) Web interface or the ipmitool program interface, the value ofFan xB Tach is not available. x represents the fan ID. - Power supply:
- Two hot-swap power supplies for redundancy support
- 900-watt ac 80 PLUS Platinum
- 1500-watt ac 80 PLUS Platinum
Note- Power supplies and redundant power supplies in the server must be with the same power rating, wattage or level.
- You may use the Power Configurator utility to determine current system power consumption. For more information and to download the utility, go to the IBM Power Configurator website.
- Two hot-swap power supplies for redundancy support
- Acoustical noise emissions:
- Sound power, idling: 6.4 bels maximum
- Sound power, operating: 6.6 bels maximum
Note- The noise emission level stated is the declared (upper limit) sound power level, in bels, for a random sample of machines. All measurements are made in accordance with ISO 7779 and reported in conformance with ISO 9296.
- The PCIe options supported in this system vary greatly in function, power draw, and required cooling. Any increase in cooling required by these options will result in increased fan speed and produced sound power level. The actual sound pressure levels measured in your installation depend upon a variety of factors, including the number of racks in the installation; the size, materials, and configuration of the room; the noise levels from other equipment; the room ambient temperature and pressure, and employees' location in relation to the equipment.
- Heat output:
- Approximate heat output:
- Minimum configuration: 525.45 Btu per hour (AC 154 watts)
- Maximum configuration: 6667 Btu per hour (AC 1954 watts)
- Environment:
The Lenovo Converged HX Series appliance complies with ASHRAE class A3 specifications.
Power on:- Temperature: 5°C–40°C (41°F–104°F) up to 950 m (3117 ft). Above 950 m (3117 ft), de-rated maximum air temperature is 1°C (33.8°F) per 175 m (574 ft).
- Humidity, non-condensing: -12°C dew point (10.4°F) and 8%–85% relative humidity.
- Maximum dew point: 24°C (75°F)
- Maximum altitude: 3050 m (10000 ft) and 5°C–28°C (41°F–82°F)
- Maximum rate of temperature change: 20°C/hr (68°F/hr) for HDDs
Power off:- Temperature: 5°C–45°C (41°F–113°F)
- Relative humidity: 8%–85%
- Maximum dew point: 27°C (80.6°F)
Storage (non-operating):- Temperature: 1°C–60°C (33.8°F–140°F)
- Altitude: 3050 m (10000 ft)
- Relative humidity: 5%–80%
- Maximum dew point: 29°C (84.2°F)
Shipment (non-operating):- Temperature: -40°C–60°C (-40°F–140°F)
- Altitude: 10,700 m (35105 ft)
- Relative humidity: 5%–100%
- Maximum dew point: 29°C (84.2°F)
Attention:- Design to ASHRAE Class A3, ambient of 40°C (104°F), with relaxed support:
- Support cloud like workload with no performance degradation acceptable (Turbo-Off).
- Under no circumstance, can any combination of worst case workload and configuration result in system shutdown or design exposure at 40°C (104°F).
- Chassis is powered on.
- A3 - Derate maximum allowable temperature 1°C (33.8°F) per 175 m (574 ft) above 950 m (3117 ft).
- The minimum humidity level for class A3 is the higher (more moisture) of the -12°C (10.4°F) dew point and the 8% relative humidity. These intersect at approximately 25°C (77°F). Below this intersection (~25°C) the dew point (-12°C) represents the minimum moisture level, while above it relative humidity (8%) is the minimum.
- Moisture levels lower than 0.5°C (32.9°F) dew point, but not lower -10°C (14°F) dew point or 8% relative humidity, can be accepted if appropriate control measures are implemented to limit the generation of static electricity on personnel and equipment in the data center. All personnel and mobile furnishings and equipment must be connected to ground via an appropriate static control system. The following items are considered the minimum requirements:
- Conductive materials (conductive flooring, conductive footwear on all personnel that go into the datacenter, all mobile furnishings and equipment will be made of conductive or static dissipative materials).
- During maintenance on any hardware, a properly functioning wrist strap must be used by any personnel who contacts IT equipment.
- 5°C/hr (41°F/hr) for data centers employing tape drives and 20°C/hr (68°F/hr) for data centers employing disk drives.
- Chassis is removed from original shipping container and is installed but not in use, for example, during repair, maintenance, or upgrade.
- The equipment acclimation period is 1 hour per 20°C (68°F/hr) of temperature change from the shipping environment to the operating environment.
- Condensation is acceptable, but not rain.
When the ambient temperature is higher than 36°C (96.8°F), 135-watt and 145-watt microprocessors might face performance degradation when operating a heavy workload.
- Your server supports the active Graphics Processing Unit (GPU) only. To support the GPU, observe the following system requirements:
Chassis GPU wattage Ambient temperature CPU wattage 2.5-inch-drive chassis Not exceed 300 watt Not exceed 35°C (95°F) No special requirement When the ambient temperature is above 35°C (95°F), the GPU is not supported due to thermal limitation.
Particulate contamination: airborne particulates and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the server. For information about the limits for particulates and gases, see Particulate contamination.