Chassis rear view

The following illustrations show the rear view of the ThinkSystem D3 Chassis.

Note
  1. Depending on the specific configuration, the hardware might look slightly different from the illustrations in this section.

  2. The ThinkSystem D3 Chassis can contain up to four 1U nodes or up to two 2U nodes.

Important
  • For proper cooling, each node tray must be installed with either a node or node tray fillers before the nodes in the chassis are powered on.

D3 Chassis rear view

Figure 1. Chassis rear view
Chassis rear view
Table 1. Components on the rear view of the D3 Chassis
1 PSU slot 1 (the PSU must be installed with the fan downward)4 Node trays (the nodes must be installed right-side up)
2 PSU slot 2 (the PSU must be installed with the fan upward)5 Node trays (the nodes must be installed upside down)
3 PSU slot 3 (the PSU must be installed with the fan upward) 

1 / 2 / 3 PSU slots

Install power supply units to these slots, connect them to power cords. Make sure the power cords are connected properly.

Important
When installing the power supply units, make sure to follow the instruction on the label in each slot.
  • For slot 1 (1), the PSU must be installed with the fan downward.
  • For slots 2 and 3 (2 and 3), the PSU must be installed with the fan upward.
Following are the power supplies supported by the system:
  • CRPS 1300-watt Titanium, input power 200-240V
  • CRPS 1300-watt Platinum, input power 200-240V
  • CRPS 1600-watt Titanium, input power 200-240V
  • CRPS 2000-watt Titanium, input power 200-240V
  • CRPS 2700-watt Titanium, input power 200-240V
  • CRPS 2700-watt Platinum, input power 200-240V

For more information on the power supply LED, see Power supply LED.